Laserfiche WebLink
<br />October 15 and once in January. The project developer shall enter into a mainte- <br />nance agreement for the oil/water separator. <br /> <br />65. The trash enclosure area(s) shall be completely covered. An area drain shall be in- <br />stalled in the enclosure area which connects to the sanitary sewer. A structural <br />control such as an oil/water separator or sand filter shall be provided. No other <br />area shall drain into the trash enclosure; a berm shall be installed to prevent such <br />drainage if found necessary by the City Engineer/Director of Building Inspection. <br />A sign shall be posted prohibiting the dumping of hazardous materials into the <br />sanitary sewer. The project developer shall notify the Dublin-San Ramon Services <br />District (DSRSD) upon installation of the sanitary connection; a copy of this noti- <br />fication shall be provided to the Planning Department. <br /> <br />66. The project developer shall sweep or vacuum the parking lot and sidewalks a mini- <br />mum of once a month and shall prevent the accumulation oflitter and debris on the <br />site. Comers and hard to reach areas shall be swept manually. If sidewalks and/or <br />the parking lot are pressure washed, debris must be trapped and collected to pre- <br />vent entry into the storm drain system. No cleaning agent may be discharged into <br />the storm drain. If any cleaning agent or degreaser is used, wash water must be <br />collected and discharged to the sanitary sewer, subject to approval of the Dublin- <br />San Ramon Services District (DSRSD). <br /> <br />67. The project developer shall label all on-site storm drain inlets with the wording, <br />"No Dumping -- Drains to Bay" using City-approved methods and materials. On- <br />site storm drain facilities shall be cleaned a minimum of twice a year as follows: <br />immediately prior to October 15 and once in January. Additional cleaning may be <br />required if found necessary by the City EngineerfDirector of Building Inspection. <br /> <br />68. Fuel dispensing areas shall be covered with canopies; canopy downspouts shall be <br />routed to prevent drainage flow across the fuel dispensing area. Fuel dispensing <br />areas shall be located on concrete surfaces which extend at least eight feet (8' 0") <br />from the face of the fuel dispenser and at least four feet (4' 0") from the nose of the <br />pump island. The surface must be graded and constructed to prevent drainage flow <br />across the fueling area. The fuel dispensing area shall be dry-swept routinely, and <br />dispensing equipment shall be inspected routinely for proper functioning and leak <br />prevention. The facility shall have a spill clean-up plan approved by the Fire De- <br />partment. <br /> <br />Planning Commission Conditions of Approval <br />Case PUD-97-14 (Chevron) <br /> <br />July 29, 1998 <br />Page 11 of 13 <br />