Laserfiche WebLink
g. On -site fire hydrants shall not be obstructed and shall be sufficiently above grade to <br />have all hydrant valves and outlets accessible for emergency use. <br />h. Where a project is phased as part of the development approved by the City, specific <br />access, water supply and fire hydrant installations will be required as part of each <br />phase. As needed a phasing plan with these improvements will be required. <br />i. Where on -site grading /utility plans are submitted for review and approval prior to <br />building construction drawings, emergency vehicle access routes, fire hydrant <br />locations, material staging areas, etc. shall be provided. <br />153. The following schedule for NO PARKING signs shall apply: <br />Width Requirements <br />36 Feet or Greater No Requirements <br />Between 28 and 36 Feet Post one side <br />Between 20 and 28 feet Post both sides <br />Less than 20 feet Not permitted <br />CODE CONDITIONS <br />(Applicants/Developers are responsible for complying with all applicable Federal, State and City <br />codes and regulations regardless of whether or not the requirements are part of this list. <br />The following items are provided for the purpose of highlighting key requirements.) <br />Building and Safety Division <br />154. The project developer shall submit a building survey and /or record of survey and a site <br />development plan in accordance with the provisions of Chapter 18.68 of the Municipal <br />Code of the City of Pleasanton. These plans shall be approved by the Chief Building and <br />Safety Official prior to the issuance of a building permit. The site development plan shall <br />include all required information to design and construct site, grading, paving, drainage, and <br />utilities. <br />155. The project developer shall post address numerals on the buildings so as to be plainly <br />visible from all adjoining streets or driveways during both daylight and night time hours. <br />156. The buildings covered by this approval shall be designed and constructed to meet Title 24 <br />state energy requirements. <br />157. All building and /or structural plans must comply with all codes and ordinances in effect <br />before the Building and Safety Division will issue permits. <br />Livermore - Pleasanton Fire Department <br />158. All construction covered by this approval shall conform to the requirements of the California <br />Building Code currently in effect, the California Fire Code currently in effect, and the City of <br />Pleasanton Ordinance 2153. All required permits shall be obtained. <br />PUD -110, Irby Ranch City Council <br />Page 26 of 32 <br />