My WebLink
|
Help
|
About
|
Sign Out
07
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2016
>
111516
>
07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2016 1:08:17 PM
Creation date
11/10/2016 11:02:17 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
11/15/2016
DESTRUCT DATE
15Y
DOCUMENT NO
07
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.10.030 CRC Chapter 1 Division II deleted. <br /> Chapter 1 Division II is deleted and replaced by Chapter 20 04, the Pleasanton Building <br /> Administrative Code <br /> 20.10.040 CRC Table R301.2(1) amended — Climate and Geographic Design <br /> Criteria. <br /> Table R301 2(1) is amended to read as follows <br /> TABLE R301.2(1) <br /> CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br /> WIND DESIGN SUBJECT TO DAMAGE FROM ICE <br /> GROUND Wind- SEISMIC WINTER BARRIER AIR MEAN <br /> Special Frost FLOOD <br /> SNOW Speed° Topographic wind borne DESIGN Weatherin line Termite. DESIGN UNDER <br /> HAZARDS" FREEZING, ANNUAL <br /> LOAD (mph) effects" , debris CATEGORY' ° TEMP° LAYMENT INDEX' TEMPI <br /> Region zone°' depth REQUIRED" <br /> N/A <br /> 85 NO NO NO Do, DE' Negligible N/A Heavy 32 ° NO noteegt 2% 58 7° <br /> D2,For SI 1 pound per square foot=0 0479 kPa, 1 mile per hour=0 447 m/s <br /> a The weathering index for the City of Pleasanton is classified as"negligible" <br /> b The City of Pleasanton does not require additional depth of footing below finish grade <br /> c The City of Pleasanton has a history of local subterranean termite damage <br /> d The City of Pleasanton is in the 85 mph wind speed zone <br /> e The outdoor design dry-bulb temperature for the City of Pleasanton was selected from the columns of 97%-percent values for <br /> winter from Appendix D of the International Plumbing Code <br /> f The City of Pleasanton is in Seismic design categories D°,D,, D2 and E <br /> g The date of the City of Pleasanton's entry into the National Flood Insurance Program May 5, 1971 <br /> The date(s)of the Flood Insurance Study August 3,2009 The panel numbers of all currently effective FIRMs adopted by the City <br /> of Pleasanton,as amended <br /> Panel 06001C0304G,Panel 06001C0308G, Panel 06001C0309G, Panel 06001C0316G, Panel 06001C0317G, <br /> Panel 06001C0318G, Panel 06001C0319G, Panel 06001C0328G,Panel 06001C0336G, Panel 06001C0337G, <br /> Panel 06001C0339G, Panel 06001 C0343G, Panel 06001C0460G,Panel 06001C0476G, Panel 06001 C0480G, and <br /> Panel 06001C0485G <br /> h The City of Pleasanton does not have a history of local damage from the effects of ice damming <br /> i The City of Pleasanton selected the 100-year(99%)value on the National Climatic Data Center data table"Air Freezing Index- <br /> USA Method(Base 32°)"at www ncdc noaa gov/fpsf html <br /> i The City of Pleasanton selected the mean annual temperature from the National Climatic Data Center data table"Air Freezing <br /> Index-USA Method(Base 32°F)"at www ncdc noaa qov/fpsf html <br /> k There is not any local historical data documenting structural damage to buildings due to topographic wind speed-up effects in the <br /> City of Pleasanton <br /> I The City of Pleasanton is not in a Special Wind Region <br /> m The City of Pleasanton is not in a Wind-borne debris zone <br /> 20.10.050 CRC Section R313 amended— Automatic Fire Sprinkler Systems. <br /> Section R313 is deleted in its entirety and amended to read as follows <br /> R313.1 Automatic Fire Sprinkler Systems. An automatic residential fire sprinkler system <br /> shall be designed and installed in accordance with NFPA 13D in all new one- and two- <br /> family dwellings and townhouses In addition, the fire-sprinkler system shall be designed <br /> and sprinklers shall be installed in the following locations <br /> 1 Attic shall be provided with intermediate temperature-rated residential fire sprinklers <br /> for detection coverage, and located at a spacing equivalent to 30 feet by 30 feet <br /> centers and a maximum distance of 15 feet from outside walls <br />
The URL can be used to link to this page
Your browser does not support the video tag.