building to more than 8,000 square feet, the entire building shall be provided <br /> with an automatic fire extinguishing system. <br /> Exception: Additions providing accessory storage space not greater than <br /> 500 square feet in area to an existing non-fire sprinklered <br /> building or solely for the purpose of providing accessibility <br /> shall not result in a requirement that the building be provided <br /> with an automatic extinguishing system. <br /> b) When a change in occupancy classification results in an increased fire <br /> hazard or risk to business operations or increased life safety hazard of the <br /> occupants, the new occupancy and all fire areas that the new occupancy <br /> exits through shall be provided with an automatic extinguishing system. <br /> Exception: Public assembly occupancies not exceeding an occupant load <br /> of 150, whether occupying an entire building or a portion of a <br /> building. <br /> 3. Existing residential buildings not currently provided with automatic fire extinguishing <br /> systems shall be provided with an automatic fire extinguishing systems as follows: <br /> a. When a modification or modifications to the building results in a 50% or greater <br /> increase of the total floor area of the building <br /> b. In the garage when a new attached or detached garage is added and the <br /> modification does not otherwise require the addition of an automatic fire <br /> protection system throughout the building. <br /> 20.24.120 CFC Section 903.3.1.2 amended - NFPA 13R Sprinkler Systems. <br /> Section 903.3.1.2 paragraph 1 is amended to read: <br /> 903.3.1.2 NFPA 13R sprinkler systems. Automatic sprinkler systems in Group R <br /> occupancies up to and including four stories in height in buildings not exceeding 60 feet <br /> (18 288 mm) in height above grade plan shall be permitted to be installed throughout in <br /> accordance with NFPA 13R as amended in Chapter 80 and the following: <br /> • Sprinklers shall be provided in all attic areas <br /> 20.24.130 CFC Section 903.3.1.3 amended - NFPA 13D Sprinkler Systems. <br /> Section 903.3.1.3 is amended to read: <br /> 903.3.1.3 NFPA 13D sprinkler systems. Automatic sprinkler systems installed in one- and <br /> two-family dwellings; Group R-3; and townhouses shall be permitted to be installed <br /> throughout in accordance with NFPA 13D, as amended in Chapter 80. <br />
The URL can be used to link to this page
Your browser does not support the video tag.