20.08.090 CBC Section 1905.1.7 amended -ACI 318 section 14.1.4. <br /> Section 1905.1.7 is amended to read as follows: <br /> 1905.1.7 ACI 318, Section 14.1.4. Delete ACI 318, Section 14.1.4, and <br /> replace with the following: <br /> 14.1.4 - Plain concrete in structures assigned to seismic design category C, D, E or F. <br /> 14.1.4.1- Structures assigned to Seismic Design Category C, D, E or F shall not have <br /> elements of structural plain concrete, except as follows: <br /> (a) Isolated footings of plain concrete supporting pedestals or columns are <br /> permitted, provided the projection of the footing beyond the face of the <br /> supported member does not exceed the footing thickness. <br /> Exception: In detached one- and two-family dwelling three stories or less in <br /> height, the projection of the footing beyond the face of the supported <br /> member is permitted to exceed the footing thickness. <br /> (b) Plain concrete footing supporting walls are permitted, provided the footings have <br /> at least two continuous longitudinal reinforcing bars. Bars shall not be smaller <br /> than No. 4 and shall have a total area of not less than 0.002 times the gross <br /> cross-sectional area of the footing. A minimum of one bar shall be provided at <br /> the top and bottom of the footing. Continuity of reinforcement shall be provided <br /> at corners and intersections. <br /> Exception: In detached one and two-family dwellings three stories or less in <br /> height and constructed with stud bearing walls, plain concrete footings with <br /> at least two continuous longitudinal reinforcing bars not smaller than No. 4 <br /> are permitted to have a total area of less than 0.002 times the gross cross- <br /> sectional area of the footing. <br /> 20.08.100 CBC Section 3109.4.4.2 added — Construction permit: safety features <br /> required. <br /> Section 3109.4.4.2 is amended to add the following paragraph to read as follows: <br /> An inspection to verify pool barriers are installed, functional and in compliance with the <br /> current laws and approved plans shall occur and be approved by the Building and Safety <br /> Official before water may be introduced into any pool or spa. <br /> 20.08.110 CBC Appendix Section J104 deleted. <br /> Section J104 is deleted and replaced by Chapter 20.04, the Pleasanton Building <br /> Administrative Code. <br />
The URL can be used to link to this page
Your browser does not support the video tag.