construction, the project developer shall mark all trash disposal bins "trash <br /> materials only" and all recycling bins "recycling materials only." The, project <br /> developer shall contact Pleasanton Garbage Service for the disposal of all waste <br /> from the site. <br /> Engineering Division <br /> 79. A "Conditions of Approval" checklist shall be completed and attached to all plan <br /> checks submitted for approval indicating that all conditions have been satisfied. <br /> 80. The project developer shall comply with the recommendations of the project's <br /> geotechnical consultant. The project developer's geotechnical consultant shall <br /> review and approve all foundation, retaining wall, and drainage geotechnical <br /> aspects of the final development plans to ensure that the recommendations have <br /> been properly incorporated into the development. The consultant shall certify by <br /> writing on the plans, or as otherwise acceptable to the City Engineer, that the final <br /> development plan is in conformance with the geotechnical report approved with <br /> the project. <br /> 81. The project developer shall arrange and pay for the geotechnical consultant to <br /> inspect and approve all foundation, retaining wall, and drainage geotechnical <br /> aspects of project construction. The consultant shall be present on site during <br /> grading and excavation operations. The results of the inspections and the as-built <br /> conditions of the project shall be certified in writing by the geotechnical consultant <br /> for conformance to the approved plans and geotechnical report and submitted to <br /> the City Engineer for review and approval prior to occupancy. <br /> 82. The project developer shall construct vertical P.C.C. curbs and gutters within this <br /> development unless otherwise approved by the City Engineer. When the sidewalk <br /> is adjacent to the curb and gutter, they shall be poured monolithically. <br /> 83. A water meter shall be provided to each lot of record within the development. <br /> 84. A sanitary sewer lateral with two-way cleanout (located at the back of the sidewalk <br /> or curb, whichever is applicable) shall be provided to each lot of record within the <br /> development unless otherwise approved by the City Engineer. <br /> 85. All existing service drops (PG&E Pac Bell and Cable TV) to existing homes and <br /> new services to proposed units within this development shall be installed <br /> underground in conduit to the nearest "utility approved" riser pole. The project <br /> developer shall also be responsible for paying a pro-rata share as determined by <br /> the City Engineer for undergrounding of the overhead utility lines across the project <br /> frontage. Said payment shall be due prior to the approval of the final map. <br /> 86. All dry utilities (electric power distribution, gas distribution, communication service, <br /> cable television, street lights and any required alarm systems) required to serve <br /> PUD-118 &P16-0203 4791 Augustine Street <br /> Draft Conditions of Approval 15 of 28 Mixed-Use Development <br />