Laserfiche WebLink
Building <br /> 101. The project applicants shall submit a building survey and/or record of survey and a <br /> site development plan in accordance with the provisions of Chapter 18.68 of the <br /> Municipal Code of the City of Pleasanton. These plans shall be approved by the <br /> Chief Building and Safety Official prior to the issuance of a building permit. The site <br /> development plan shall include all required information to design and construct site, <br /> grading, paving, drainage, and utilities. <br /> 102. All building and/or structural plans must comply with all codes and ordinances in <br /> effect before the Building Division will issue permits. <br /> Fire Department <br /> 103. All construction shall conform to the requirements of the California Fire Code <br /> currently in effect, City of Pleasanton Building and Safety Division and City of <br /> Pleasanton Ordinance 2015. All required permits shall be obtained. <br /> 104. Automatic fire sprinklers shall be installed in all occupancies in accordance with City <br /> of Pleasanton Ordinance 2015. Installations shall conform to NFPA Pamphlet 13 for <br /> commercial occupancies NFPA 13D for residential occupancies and NFPA 13R for <br /> multifamily residential occupancies. <br /> 105. Fire alarm system shall be provided and installed in accordance with the CFC <br /> currently in effect, the City of Pleasanton Ordinance 2015 and 2002 NFPA 72 - <br /> National Fire Alarm Code. Notification appliances and manual fire alarm boxes shall <br /> be provided in all areas consistent with the definition of a notification zone <br /> (notification zones coincide with the smoke and fire zones of a building). Shop <br /> drawings shall be submitted for permit issuance in compliance with the CFC <br /> currently in effect. <br /> 106. All buildings undergoing construction, alteration or demolition shall comply with <br /> Chapter 14 (California Fire Code currently in effect) pertaining to the use of any <br /> hazardous materials, flame- producing devices, asphalt/tar kettles, etc. <br /> 107. The.buildings covered by this approval shall conform to the requirements of the <br /> California Building Code currently in effect, the California Fire Code currently in <br /> effect and the City of Pleasanton Ordinance 2015. If required plans and <br /> specifications for the automatic fire sprinkler system shall be submitted to the <br /> Livermore-Pleasanton Fire Department for review and approval prior to installation. <br /> The fire alarm system, including water flow and valve tamper, shall have plans and <br /> specifications submitted to Fire Prevention for review and approval prior to <br /> installation. All required inspections and witnessing of tests shall be completed prior <br /> to final inspection and occupancy of the building(s). <br /> {end} <br /> PUD-116, Beriogar Page 22 <br />