Laserfiche WebLink
and installation of private sub-meters if the project is non-residential with a <br /> landscape area of 1,000 square feet or greater. <br /> 32. The residential buildings shall be constructed to allow for future installation of a <br /> Photovoltaic (PV) system and solar water heating systems. The project <br /> applicant/developer shall comply with the following requirements for making all <br /> buildings photovoltaic-ready and solar-water-heating-ready: <br /> a. Electrical conduit and cable pull strings shall be installed from the roof/attic <br /> area to the building's main electrical panels; <br /> b. An area shall be provided near the electrical panel for the installation of an <br /> "inverter" required to convert the direct current output from the photovoltaic <br /> panels to alternating current; <br /> c. Engineer the roof trusses to handle an additional load as determined by a <br /> structural engineer to accommodate the additional weight of a prototypical <br /> photovoltaic system beyond that anticipated for roofing; <br /> d. Plumbing shall be installed for solar-water heating; and <br /> e. Space shall be provided for a solar-water-heating tank. <br /> These measures shall be shown on the building permit plan set submitted to the <br /> Director of Community Development for review and approval before issuance of <br /> the first building permit. <br /> 33. The State of California's Green Building Standards Code, "CALGreen," shall apply, <br /> if applicable. <br /> 34. The golf ball fence/net structure shall be removed prior to issuance of a building <br /> permit for Phase II construction (i.e. Lots 17-19). <br /> 35. The plot plans and house model and elevation type for Lots 1-5 shall adhere to the <br /> "Lots 1-5 Preliminary Plotting Exhibit," dated "Received, March 21, 2016," on file <br /> with the Planning Division. <br /> 36. Prior to issuance of a building permit, the applicant/project developer shall provide <br /> plot plans for the five homes that will be constructed with a bonus room option. <br /> The plot plans are subject to review and approval by the Director of Community <br /> Development. <br /> 37. The location of street trees at the corners of Leah Lane/Lynn Drive and Melinda <br /> Way/Lynn Drive shall be adjusted and/or additional street trees shall be added to <br /> reduce the glare of vehicle headlights to the north. This revision shall be shown on <br /> the street improvement plan, and is subject to review and approval by the Director <br /> of Community Development and City Landscape Architect. <br /> 7 of 28 <br />