My WebLink
|
Help
|
About
|
Sign Out
20
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2016
>
041916
>
20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2016 1:53:53 PM
Creation date
4/13/2016 2:33:24 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
4/19/2016
DESTRUCT DATE
15Y
DOCUMENT NO
20
Document Relationships
20 ATTACHMENT 3
(Attachment)
Path:
\CITY CLERK\AGENDA PACKETS\2016\041916
20 ATTACHMENT 3-2
(Attachment)
Path:
\CITY CLERK\AGENDA PACKETS\2016\041916
20 ATTACHMENT 4
(Attachment)
Path:
\CITY CLERK\AGENDA PACKETS\2016\041916
20 ATTACHMENT 4-2
(Attachment)
Path:
\CITY CLERK\AGENDA PACKETS\2016\041916
20 ATTACHMENT 5
(Attachment)
Path:
\CITY CLERK\AGENDA PACKETS\2016\041916
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
119. All construction covered by this approval shall conform to the requirements of the <br />California Building Code currently in effect, the California Fire Code currently in effect, <br />and the City of Pleasanton Ordinance 2015. All required permits shall be obtained. <br />120. Automatic fire sprinklers shall be installed in all occupancies in accordance with City of <br />Pleasanton Ordinance 2015. Installations shall conform to NFPA Pamphlet 13 for <br />commercial occupancies, NFPA 13D for residential occupancies, and NFPA 13R for <br />multifamily residential occupancies. <br />121. Underground fire mains, fire hydrants and control valves shall be installed in conformance <br />with the most recently adopted edition of NFPA Pamphlet 24, "Outside Protection." <br />• The underground pipeline contractor shall submit a minimum of three (3) sets of <br />installation drawings to the Fire Department Fire Prevention Bureau. The plans shall <br />have the contractor's wet stamp indicating the California contractor license type and <br />license number and must be signed. No underground pipeline inspections will be <br />conducted prior to issuance of approved plans. <br />• All underground fire protection work shall require a California contractor's license type <br />as follows: C -16, C -34, C -36 or A. <br />• All field- testing and inspection of piping joints shall be conducted prior to covering of <br />any pipeline. <br />122. Dead -end fire service water mains shall not exceed 500 feet in length and /or have more <br />than five Fire Department appliances" shall be looped around the site or building and <br />have a minimum of two points of water supply or street connection. Zone valves shall be <br />installed as recommended under NFPA, Pamphlet 24 and the Fire Marshal. <br />`Note: Fire Department appliances are classified as fire sprinkler system risers, fire <br />hydrants, and /or standpipes. <br />123. All buildings undergoing construction, alteration or demolition shall comply with Chapter <br />14 (California Fire Code currently in effect) pertaining to the use of any hazardous <br />materials, flame - producing devices, asphalt/tar kettles, etc. <br />URBAN STORMWATER CONDITIONS <br />124. The project shall comply with the NPDES Permit No. CAS612008, dated October 14, <br />2009, and amendments, issued the by California Regional Water Quality Control Board, <br />San Francisco Bay Region, a copy of which is available at the Community Development <br />Department, Public Works /Engineering section at City offices, Alameda County Clean <br />Water Program, State Water Board, and at the following websites: <br />http: / /www.waterboards.ca.gov /sanfranciscobay /water issues /programs /stormwater /Muni <br />cipal /index.shtml; <br />and <br />http: / /www.waterboards.ca.gov /sanfranciscobay /board info /agendas /2007 /march /alamed <br />a %20final %20order %20x2- 2007 -0025. pdf <br />
The URL can be used to link to this page
Your browser does not support the video tag.