My WebLink
|
Help
|
About
|
Sign Out
RES 16835
City of Pleasanton
>
CITY CLERK
>
RESOLUTIONS
>
2010-2019
>
2016
>
RES 16835
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2017 11:04:53 AM
Creation date
3/3/2016 1:05:59 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
3/1/2016
DESTRUCT DATE
PERMANENT
DOCUMENT NO
16835
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Resolution No.16-835 <br /> Exhibit A <br /> Building and Safety Division <br /> 126. The project applicant or developer shall submit a building survey and/or record of <br /> survey and a site development plan in accordance with the provisions of Chapter <br /> 18.68 of the Municipal Code of the City of Pleasanton. These plans shall be <br /> approved by the Chief Building and Safety Official prior to the issuance of a <br /> building permit. The site development plan shall include all required information <br /> to design and construct site, grading, paving, drainage, and utilities. <br /> 127. The project applicant or developer shall post address numerals on the building so <br /> as to be plainly visible from all adjoining streets or driveways during both daylight <br /> and night time hours. <br /> 128. All building and/or structural plans must comply with all codes and ordinances in <br /> effect before the Building and Safety Division will issue permits. <br /> Livermore-Pleasanton Fire Department <br /> 129. All construction shall conform to the requirements of the California Fire Code <br /> currently in effect, City of Pleasanton Building and Safety Division and City of <br /> Pleasanton Ordinance 2015. All required permits shall be obtained. <br /> 130. Automatic fire sprinklers shall be installed in all occupancies in accordance with <br /> City of Pleasanton Ordinance 2015. Installations shall conform to NFPA <br /> Pamphlet 13D for residential occupancies. <br /> 131. Fire alarm system shall be provided and installed in accordance with the CFC <br /> currently in effect, the City of Pleasanton Ordinance 2015 and 2002 NFPA 72 - <br /> National Fire Alarm Code. Notification appliances and manual fire alarm boxes <br /> shall be provided in all areas consistent with the definition of a notification zone <br /> (notification zones coincide with the smoke and fire zones of a building). Shop <br /> drawings shall be submitted for permit issuance in compliance with the CFC <br /> currently in effect. <br /> 132. Underground fire mains, fire hydrants and control valves shall be installed in <br /> conformance with the most recently adopted edition of NFPA Pamphlet 24, <br /> "Outside Protection." <br /> m The underground pipeline contractor shall submit a minimum of three (3) sets <br /> of installation drawings to the Fire Department, Fire Prevention Bureau. The <br /> plans shall have the contractor's wet stamp indicating the California contractor <br /> license type, license number and must be signed. No underground pipeline <br /> inspections will be conducted prior to issuance of approved plans. <br /> ® All underground fire protection work shall require a California contractor's <br /> license type as follows: C-16, C-34, C-36 or A. • <br /> Page 23 of 31 <br />
The URL can be used to link to this page
Your browser does not support the video tag.