Laserfiche WebLink
If an exception is not feasible, noise mitigation measures would be required to reduce the noise <br /> 22 feet away by approximately 5 to 6 dBA. The only practical option would be a sound wall or a <br /> specially-designed wooden fence structure capable of reducing noise levels by 5 to 6 dBA. Based <br /> on the proposed plans for the 7-Eleven carwash, the clearance at the exit would have a height of <br /> eight feet; therefore, the minimum height for the proposed noise barrier would also need to be <br /> eight feet. The proposed noise barrier would start at the wall of the exit and extend slightly east, <br /> just outside the exit driveway of the carwash. Positioning the wall a few feet away from the edge <br /> of the exit driveway is recommended for the benefit of the carwash customers. The total length <br /> of the proposed noise barrier, which is shown in Figure 5, would be approximately 55 to 60 feet. <br /> The southernmost section of the proposed barrier extends beyond point of required mitigation <br /> due to the corner effects of noise barriers. This extension is recommended to ensure effectiveness <br /> of the sound mitigation measure. <br /> The proposed noise barrier design consists of a fence with two solid wood layers rigidly <br /> connected. There should be no holes or gaps anywhere along either layer of wood. Furthermore, <br /> there should not be any gap where the fence touches the ground. All joints between the wooden <br /> boards or sheets of wood should be supported by structural elements or caulked. Additionally, a <br /> layer of sound-absorptive material could be applied between the two parallel wooden fence <br /> layers. An alternative design could include a sound wall of the same dimensions made out of <br /> stucco or blocks. Similar to the wooden fence design, sound walls made of these materials would <br /> also need to be solid, with no holes or gaps on the wall or at the base of the wall where it meets <br /> the ground. The total noise reduction that could be expected from both the proposed fence and <br /> the sound wall designs would be at least 5 to 6 dBA. Figure 5 shows the predicted noise levels <br /> just inside the proposed noise barrier and the distance at which these levels were calculated. <br /> Figure 6 shows the predicted noise levels at the south and southeast locations of the property <br /> line, assuming the 8- to 10-foot noise barrier was constructed as shown. A noise expert should be <br /> consulted during the final design phase of the project to confirm final design and dimensions. <br /> Page 17 <br />