My WebLink
|
Help
|
About
|
Sign Out
ORD 2107
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2101 - 2200
>
ORD 2107
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:25 PM
Creation date
10/10/2014 12:36:13 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
9/16/2014
DESTRUCT DATE
PERMANENT
DOCUMENT NO
2107
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
171. Automatic fire sprinklers shall be installed in all occupancies in accordance with <br /> City of Pleasanton Ordinance 2015. Installations shall conform to NFPA <br /> Pamphlet 13 for commercial occupancies. <br /> 172. Fire alarm system shall be provided and installed in accordance with the CFC <br /> currently in effect, the City of Pleasanton Ordinance 2015 and 2010 NFPA 72 - <br /> National Fire Alarm Code. Notification appliances and manual fire alarm boxes <br /> shall be provided in all areas consistent with the definition of a notification zone <br /> (notification zones coincide with the smoke and fire zones of a building). Shop <br /> drawings shall be submitted for permit issuance in compliance with the CFC <br /> currently in effect. <br /> 173. City of Pleasanton Ordinance 2015 requires that all new and existing <br /> occupancies be provided with an approved key box from the Knox Company as <br /> specified by the Fire Department. The applicant is responsible for obtaining <br /> approval for location and the number of boxes from the Fire Prevention Bureau. <br /> Information and application for Knox is available through their website or the Fire <br /> Prevention Bureau. Occupant shall be responsible for providing tenant space <br /> building access keys for insertion into the Knox Box prior to final inspection by <br /> the Fire Department. Keys shall have permanent marked tags identifying <br /> address and/or specific doors/areas accessible with said key. <br /> 174. Underground fire mains, fire hydrants and control valves shall be installed in <br /> conformance with the most recently adopted edition of NFPA Pamphlet 24, <br /> "Outside Protection". <br /> • The underground pipeline contractor shall submit a minimum of three (3) sets <br /> of installation drawings to the Fire Department, Fire Prevention Bureau. The <br /> plans shall have the contractor's wet stamp indicating the California contractor <br /> license type, license number and must be signed. No underground pipeline <br /> inspections will be conducted prior to issuance of approved plans. <br /> • All underground fire protection work shall require a California contractor's <br /> license type as follows: C-16, C-34, C-36 or A. <br /> • All field-testing and inspection of piping joints shall be conducted prior to <br /> covering of any pipeline. <br /> 175. Portable fire extinguisher(s) shall be provided and installed in accordance with <br /> the California Fire Code currently in effect and Fire Code Standard #10-1. <br /> Minimum approved size for all portable fire extinguishers shall be 2A 10B:C. <br /> Building <br /> 176. The project developer shall submit a building survey and/or record of survey and <br /> a site development plan in accordance with the provisions of Chapter 18.68 of <br /> the Municipal Code of the City of Pleasanton. These plans shall be approved by <br /> the Chief Building and Safety Official prior to the issuance of a building permit. <br /> The site development plan shall include all required information to design and <br /> construct site, grading, paving, drainage, and utilities. <br /> PUD-106, Chrylser-Jeep-Dodge Page 32 <br />