My WebLink
|
Help
|
About
|
Sign Out
21
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2014
>
081914
>
21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2015 4:39:43 PM
Creation date
8/12/2014 2:29:00 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
8/19/2014
DESTRUCT DATE
15Y
DOCUMENT NO
21
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
yet <br /> maintain 14 feet clear area above the roadway (20 feet). The water <br /> and sewer laterals and storm drain system within the driveways <br /> shall be private and maintained by the individual property owners or <br /> HOA. <br /> b. The Typical Private Driveway Section (without bridges): <br /> The driveway section shall be a minimum of 16 feet wide paved <br /> surface with 2 feet of class II aggregate base rock on both sides of <br /> the driveway unless otherwise approved by the Fire Marshall. The <br /> structural section of the driveway shall support the Fire apparatus <br /> and maintenance vehicle as determined by the City Engineer. The <br /> minimum outside radius of the driveway shall be 55 feet. The <br /> maximum grade of the driveway shall be 15 percent except at <br /> driveway intersections where the grade shall not exceed 7 percent. <br /> The landscaping shall be trimmed back to maintain 14 feet clear <br /> area above the roadway (20 feet). The water and sewer laterals <br /> and storm drain system within the driveways shall be private and <br /> maintained by the individual property owners or HOA. <br /> 6. The typical lot side slope shall be 3:1 maximum, unless otherwise <br /> approved by the City Engineer. <br /> 7. The concrete V-ditch located between the lots shall extend down the slope <br /> and tie into the V-ditch along the north and south sides of the development <br /> unless otherwise approved by the City Engineer. <br /> 8. The homeowners association shall maintain the Filterra stormwater <br /> filtering system unless otherwise approved by the City Engineer. <br /> 9. The subdivider's engineer shall demonstrate to the satisfaction of the City <br /> Engineer that the Filterra stormwater filtering system will capture a <br /> minimum of 0.2 inches per hour storm with a 15 percent street grade. <br /> 10. The northeasterly curb return at the intersection of Austin Place and the <br /> City parking lot the radius shall be adjusted to accommodate the fire truck <br /> otherwise approved by the City Engineer <br /> 11. If the existing home is to remain the overhead utilities serving the home <br /> shall be underground as part of the subdivision improvements. The <br /> subdivider shall convert these homes from overhead services to <br /> underground. <br /> 12. The curb and gutter of all streets within the development, shall have <br /> subdrains installed at either the back of curb or lip of gutter at the <br /> discretion of the City Engineer. This detail shall be shown on the <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.