Laserfiche WebLink
Engineer/Chief Building Official for review and approval prior to the issuance <br /> of a grading or budding permit, whichever is sooner. The structural control <br /> shall be cleaned at least twice a year (once immediately prior to October 15 <br /> and once in January). <br /> c. The project developer shall submit to the City Engineer the sizing design <br /> criteria and calculations for Trash Capture Devices (TCDs), and for the <br /> treatment of stormwater runoff. The design criteria and calculations shall be <br /> subject to the review and approval of the City Engineer and shall be <br /> submitted prior to the issuance of a grading or building permit, whichever is <br /> sooner. <br /> d. Building/Structures shall be designed to minimize the occurrence and entry of <br /> pests into buildings, thus minimizing the need for pesticides, as determined <br /> by the Chief Building Official prior to the issuance of a building permit. <br /> e. The project's landscape and irrigation plans shall be designed to: 1) minimize <br /> the use of fertilizers and pesticides that can contribute to stormwater pollution; <br /> and 2) promote surface infiltration. Prior to the installation of project <br /> landscaping and irrigation, the project landscape architect shall submit a <br /> landscaping and irrigation plan to the City Engineer for review and approval <br /> and submit written verification stating the project incorporates the following: <br /> i. Plants tolerant of saturated soil conditions and prolonged exposure to <br /> water in areas that provide detention of water. <br /> ii. Plants and soil,amendments appropriate to site specific characteristics <br /> such as topography and climate. <br /> iii. Landscaping and irrigation consistent with Bay-Friendly Landscaping. <br /> iv. Water conservation techniques to promote surface infiltration. <br /> f. Trash dumpsters and recycling containers shall be in an enclosed and roofed <br /> area to minimize water flowing in and from the area and to contain litter and <br /> trash to minimize disbursement by the wind or runoff. These areas shall not <br /> drain to the storm drain system, but to the sanitary sewer system. An area <br /> drain shall be installed in the enclosure area with a structural control such as <br /> an oil/water separator or sand filter. No other area shall drain into the trash <br /> enclosure; a ridge or a berm shall be constructed to prevent such drainage if <br /> found necessary by the City Engineer/Chief Building Official. A sign shall be <br /> posted prohibiting the dumping of hazardous materials into the sanitary <br /> sewer. The project developer shall notify the Dublin San Ramon Services <br /> District of the sanitary sewer connection and provide written verification of <br /> such notification to the City Engineer/Chief Building Official prior to the <br /> installation of the connection. <br /> PUD-98, CarMax Auto Superstores Page 32 <br />