My WebLink
|
Help
|
About
|
Sign Out
20 Attach 1 and 2
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2014
>
050614
>
20 Attach 1 and 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2015 4:15:05 PM
Creation date
4/30/2014 11:19:45 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
5/6/2014
DESTRUCT DATE
15Y
DOCUMENT NO
20 ATTACHMENTS 1 and 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
63. In accordance with measure VQ-3.2, the project developer shall design lighting <br /> systems to provide appropriate light illumination for the proposed project and <br /> protect surrounding uses from spillover light and glare by incorporating the <br /> following guidelines and specifications: <br /> a. Prior to the issuance of a building permit, a lighting plan that includes <br /> specifications for pylon signs, monument signs and exterior lighting <br /> shall be submitted for review and approval by the Director of <br /> Community Development. The plan shall include a photometric <br /> diagram, prepared by a certified lighting professional, showing <br /> predicted maintained lighting levels produced by the proposed lighting <br /> fixture facilities that achieve the following during hours of operation: <br /> i. The first row of light standards shall not exceed a foot candle <br /> level of 50.0 by the northern boundary and 35.0 by the eastern <br /> and southern boundaries as measured at ground level. <br /> ii. The foot candle level for the remainder of the project site shall <br /> not exceed 10.0 foot candles as measured at ground level, <br /> except: <br /> • In designated display areas where merchandise is <br /> presented to customers, the foot candle level may be up to, <br /> but not exceed, 30.0 at ground level; and <br /> • At the senior continuing care community, foot candle spill <br /> over from the project site shall not exceed 1.0 foot candle at <br /> ground level. <br /> iii. Lighting fixtures for automobile sales and services shall not <br /> exceed 25 feet in height, for ground mounted poles. <br /> iv. Unless otherwise approved by the Director of Community <br /> Development, lighting fixtures for parking and security purposes <br /> within the project site that are adjacent to the senior continuing <br /> care community shall not exceed 14 feet in height and shall <br /> be fully-shielded to reduce spill light directly on to the <br /> residences at the community. <br /> b. During non-operational evening hours, all exterior parking lot lighting <br /> levels shall be designed such that they do not exceed 10 foot candles. <br /> The lighting plan submitted to the Building and Safety Division with plan <br /> check plans shall be modified to comply with these measures. <br /> 64. In accordance with measure VQ-3.3, all interior lighting shall be turned off during <br /> non-operational evening hours, with the exception of lighting needed for security <br /> reasons. <br /> PUD-98, CarMax Auto Superstores Page 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.