Laserfiche WebLink
Ordinance No.2083 <br /> Page 14 <br /> D. Where there is a reference in the code to the "Building Official" or "Authority Having <br /> Jurisdiction" it shall mean the "Building and Safety Official" or in the absence of the <br /> Building and Safety Official, the interim, temporary or acting Building and Safety <br /> Official. <br /> 20.10.020 CRC Chapter 1 Division II is deleted. <br /> Chapter 1 Division II is deleted. <br /> 20.10..430 CRC Section R202 amended — Definitions <br /> Section R202 is amended by adding the following definition to read as follows: <br /> BALCONY, EXTERIOR, is an exterior floor projecting from and supported by a <br /> structure, without additional independent supports. <br /> 20.10.040 CRC Table R301.2(1) amended — Climate and Geographic Design <br /> Criteria <br /> Table R301.2(1) is amended to read as follows: <br /> TABLE R301.2(1) <br /> CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br /> SUBJECT TO DAMAGE ICE <br /> WIND FROM BARRIER <br /> GROUND SEISMIC Frost WINTER UNDER- AIR MEAN <br /> SNOW Speed° Topographic DESIGN line DESIGN LAYMENT FLOOD FREEZING ANNUAL <br /> LOAD {mph) effects" CATEGORY' Weathering' depth' Termite` TEMP` REQUIRED" HAZARDS° INDEX' TEMP' <br /> 85 Do, Dt, Very <br /> N/A mph NO D2, E negligible N/A Heavy 32° NO Footnote g 2% 58.7° <br /> For SI: 1 pound per square foot=0.0479 LPa. 1 mile per hour=0.447 m/s. <br /> a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. <br /> The weathering column shall be filled in with the weathering index(i.e.,"negligible,""moderate or"severe")for concrete as determined <br /> from the Weathering Probability Map/Figure R301.2(3)1.The grade of masonry units shall be determined from ASTM C 34,C 55,C'62.C <br /> 73,C 90,C 129,C 145,C 216 or C 652. <br /> b. The frost line depth may require deeper footings than indicated in Figure R403.1(1).The City of Pleasanton does not require additional <br /> depth of footing below finish grade. <br /> c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local <br /> subterranean termite damage. <br /> d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[FigureR301.2(4)].Wind exposure <br /> category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. <br /> e. The outdoor design dry-bulb temperature was selected from the columns of 971/2-percent values for winter from Appendix D of the <br /> /nteenational Plumbing Code. <br /> f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section 1(301.2.2.1. <br /> g. The date of the City of Pleasanton's entry into the National Flood Insurance Program: May 5, 1971. <br /> The date(s)of the Flood Insurance Study:August 3,2009;September 30, 1997:September 19, 1984:June 1980 revised August 31. 1982. <br /> The panel numbers and dates of all currently effective FIRMs adopted by the City of Pleasanton,as amended: Panel 06001 Ct)304G;Panel <br /> 0601)IC0308G;Panel 06001C03090;Panel 06001CO3I6G:Panel 06001 C0317G: Panel 06001003180:Panel 06001003190:Panel <br /> 06001C0328G;Panel 06001C03360:Panel 0600IC0337G:Panel 06001C0339G:Panel 06001C0343G:Panel 06001C0460G:Panel <br /> 06001C0476G;Panel 06001C04800:and Panel 06001C0485G.all effective August 3.2009. <br /> h. In accordance with Sections R905.2 7.1,R905 4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of <br /> local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall <br /> fill in this part of the table with"NO.- <br /> i. The City of Pleasanton selected the 100-year(99%)value on the National Climatic Data Center data table"Air Freezing Index-USA <br /> Method(Base 32T at www.ncdc.noaa.gov/fpsfluinl. <br />