Laserfiche WebLink
cross-sectional area of the footing. A minimum of one bar shall be provided at the <br /> top and bottom of the footing. Continuity of reinforcement shall be provided at <br /> corners and intersections. <br /> Exception: In detached one and two-family dwellings three stories or less in <br /> height and constructed with stud bearing walls, plain concrete footings with at <br /> least two continuous longitudinal reinforcing bars not smaller than No. 4 are <br /> permitted to have a total area of less than 0.002 times the gross cross— <br /> sectional area of the footing. <br /> 20.08.120 CBC Section 1907.1 amended - Minimum Slab Provisions. <br /> Section 1907.1 is amended to read as follows: <br /> 1907.1 General. The thickness of concrete floor slabs supported directly on the ground <br /> shall not be less than 3% inches (89 mm). A minimum 10-mil (0.010 inch, .20mm) <br /> polyethylene moisture retarder with joints lapped not less than 6 inches (152 mm) shall <br /> be placed above a minimum of 4-inches (102 mm) of crushed or angular rock capillary <br /> moisture barrier or other approved equivalent methods and materials used to provide <br /> slab-stability and moisture protection of the interior environment of the building. The <br /> capillary moisture barrier material shall have a maximum particle size of 3/4-inch with no <br /> more than 10 percent smaller than 1/4—inch. In order to promote a more uniform curing <br /> of the slab and to provide protection for the polyethylene moisture retarder, a minimum <br /> of two-inches of fine clean sand shall be placed directly over the moisture retarder. As a <br /> minimum and in all cases where a slab is to be placed inside of a building, the slab shall <br /> be reinforced with not less than six inches by six inches ten gauge welded wire mesh or <br /> an approved alternate installed on approved supports at mid height of the concrete slab. <br /> Exception: A vapor retarder, sand and rock are not required: <br /> 1. For detached structures accessory to occupancies in Group R-3, such as <br /> garages, utility buildings or other unheated facilities. <br /> 2. For unheated storage rooms having an area of less than 70 square feet (6.5 <br /> m2) and carports attached to occupancies in Group R-3. <br /> 3. For buildings of other occupancies where migration of moisture through the slab <br /> from below will not be detrimental to the intended occupancy of the building and <br /> the rock is determined not to be needed for support or stability of the concrete <br /> floor slab. <br /> 4. For driveways, walks, patios and other flatwork which will not be enclosed at a <br /> later date. <br /> 5. Where approved based on local site conditions. <br /> In all slabs under habitable spaces, a minimum of 4 inches (102 mm) of crushed rock <br /> capillary water barrier shall be provided under the minimum 10 mil vapor retarder. The <br /> vapor barrier shall be protected by a minimum of 2 inches (51 mm) of sand, or <br /> equivalent protection. <br />