My WebLink
|
Help
|
About
|
Sign Out
05
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2013
>
110513
>
05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2016 2:59:34 PM
Creation date
10/31/2013 11:26:27 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
11/5/2013
DESTRUCT DATE
15Y
DOCUMENT NO
05
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ordinance No. 2083 <br /> Page 14 <br /> D. Where there is a reference in the code to the "Building Official" or "Authority Having <br /> Jurisdiction" it shall mean the "Building and Safety Official" or in the absence of the <br /> Building and Safety Official, the interim, temporary or acting Building and Safety <br /> Official. <br /> 20.10.020 CRC Chapter 1 Division II is deleted. <br /> Chapter 1 Division II is deleted. <br /> 20.10.030 CRC Section R202 amended — Definitions <br /> Section R202 is amended by adding the following definition to read as follows: <br /> BALCONY, EXTERIOR, is an exterior floor projecting from and supported by a <br /> structure, without additional independent supports. <br /> 20.10.040 CRC Table R301.2(1) amended — Climate and Geographic Design <br /> Criteria <br /> Table R301.2(1) is amended to read as follows: <br /> TABLE R301.2(1) <br /> CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br /> SUBJECT TO DAMAGE ICE <br /> WIND DESIGN FROM BARRIER <br /> GROUND SEISMIC Frost! WINTER UNDER- AIR MEAN <br /> SNOW Speed° Topographic DESIGN line DESIGN LAYMENT FLOOD FREEZING ANNUAL <br /> LOAD (mph) effects" CATEGORY' Weathering° depth" Termite' TEMP° REQUIRED" HAZARDS° INDEX' TEMP/ <br /> 85 De, D,, Very <br /> . N/A mph NO D2, E negligible N/A Heavy 32° NO Footnote g 2% 58.7° <br /> For SI: 17ound per square foot=0.0479 kPa, I mile per hour=0.447 m/s. <br /> a Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. <br /> The weathering column shall be tilled in with the weathering index(i.e.,"negligible.""moderate`or"severe')for concrete as determined <br /> front the Weathering Probability Map[Figure R301.2(3)].The grade of masonry units shall be determined from ASTM C 34,C 55,C 62,C <br /> 73,C 90,C 129,C 145,C 216 or C 652. <br /> b. The frost line depth may require deeper footings than indicated in Figure R403.10).The City of Pleasanton does not require additional <br /> depth of footing below finish grade. <br /> c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local <br /> subterranean termite damage. <br /> d The jurisdiction shall till in this part of the table with the wind speed from the basic wind speed map[FigureR301 2(4)]_Wind exposure <br /> category shall be determined on a site-specific basis in accordance with Section R3012.13_ <br /> e. The outdoor design dry-bulb temperature was selected from the columns of 971/2-percent values for winter from Appendix D of the <br /> lnleenalTonal Plumbing Code. <br /> I The jurisdiction shall fill in this part of the table with the seismic design category determined from Section 12301.2.2.1. <br /> g. The date of the City of Pleasanton's entry into the National Flood Insurance Program: May 5, 1971. <br /> The date(s)of the Flood Insurance Study:August 3,2009;September 30, 1997:September 19, 1984;June 1980 revised August 31, 1982. <br /> The panel numbers and dates of all currently effective FIRMs adopted by the City of Pleasanton.as amended: Panel 06001C0304G;Panel <br /> 06001C0308G;Panel 06001C0309G;Panel 06001C0316G:Panel 06001C03170,Panel 06001C0318G:Panel 06001C0319G;Panel <br /> 06001C0328G;Panel 06001(0336G,Panel 06001C0337G:Panel 06001C0339G,Panel 06001C0343G:Panel 06001C0460(i;Panel <br /> 06001C0476G;Panel 06001004800:and Panel 0600 IC0485G.all effective August3,2009. <br /> h. In accordance with Sections R905.2.7 1,R905.4.3 1,R905.S 3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history,of <br /> local damage from the effects of ice damming,the jurisdiction shall till in this part of the table with"YES."Otherwise,the jurisdiction shall <br /> fill in this part of the table with"NO_' <br /> i. The City of Pleasanton selected the 100-year(99%)value on the National Climatic Data Center data table"Air Freezing Index-USA <br /> Method(Base 32°)"at www.ncdcmoaa gov/fpsfhtml. <br />
The URL can be used to link to this page
Your browser does not support the video tag.