My WebLink
|
Help
|
About
|
Sign Out
03
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2013
>
101513
>
03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2016 2:56:22 PM
Creation date
10/9/2013 4:06:39 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
10/15/2013
DESTRUCT DATE
15Y
DOCUMENT NO
03
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8.1 .The pool shall be equipped with an approved powered safety cover in <br /> compliance with ASTM F 1346; or <br /> 8.2. Doors with direct access to the pool through that wall shall be equipped with <br /> an alarm which produces an audible warning when the door and/or its <br /> screen, if present, are opened. The alarm shall be listed and labeled in <br /> accordance with UL 2017. The deactivation switch(es) shall be located at <br /> least 54 inches (1372 mm) above the threshold of the door; or <br /> 8.3. Other means of protection, such as self-closing doors with self-latching <br /> devices, which are approved by the governing body, shall be acceptable as <br /> long as the degree of protection afforded is not less than the protection <br /> afforded by Item 8.1 or 8.2 described above. <br /> 9. Where an above-ground pool structure is used as a barrier or where the barrier is <br /> mounted on top of the pool structure, and the means of access is a ladder or <br /> steps: <br /> 9.1.The ladder or steps shall be capable of being secured, locked or removed to <br /> prevent access; or <br /> 9.2.The ladder or steps shall be surrounded by a barrier which meets the <br /> requirements of Section AG105.2, Items 1 through 8. When the ladder or <br /> steps are secured, locked or removed, any opening created shall not allow <br /> the passage of a 4-inch-diameter (102 mm) sphere. <br /> Prior to the issuance of any final approval for the completion of permitted construction or <br /> remodeling work, the Building and Safety Official shall inspect and verify the drowning <br /> safety prevention devices required have been installed and functional properly. <br /> AG105.3 Indoor swimming pool. Walls surrounding an indoor swimming pool shall <br /> comply with Section AG105.2, Item 8. <br /> AG105.4 Prohibited locations. Barriers shall be located to prohibit permanent <br /> structures, equipment or similar objects from being used to climb them. <br /> AG105.5 Barriers. <br /> AG105.5.1 Enclosure; required characteristics. An enclosure shall have all of the <br /> following characteristics: <br /> 1. Any access gates through the enclosure open away from the swimming pool and <br /> are self-closing with a self-latching device placed no lower than 60 inches (1524 <br /> mm) above the ground. <br /> 2. A minimum height of 60 inches (1524 mm). <br /> 3. A maximum vertical clearance from the ground to the bottom of the enclosure of <br /> 2 inches (51 mm). <br /> 4. Gaps or voids, if any, do not allow passage of a sphere equal to or greater than 4 <br /> inches (102 mm) in diameter. <br /> 5. An outside surface free of protrusions, cavities or other physical characteristics <br /> that would serve as handholds or footholds that could enable a child below the <br /> age of five years to climb over. <br />
The URL can be used to link to this page
Your browser does not support the video tag.