c. Individual stair treads shall he designed for the uniformly distributed live load or a 300-pound concentrated load acting over an area()I'4 square <br /> inches-whichever produces the greater stresses. <br /> d. A single concentrated load applied in any direction at any point along the top. <br /> e. Decks that are not exterior halconies may he designed at 10 psf, See Section R502.2.2 for decks attached to exterior walls_ <br /> I.Guard in-lilt components(all those except the handrail),balusters and panel fillers shall he designed to withstand a horizontally applied nomlal <br /> load of 511 pounds on an area equal to I square foot.This load need not he assumed to act concurrently with any other lire load requirement. <br /> g. For attics with limited storage and constructed with trusses, this live load need he applied only to those portions of the bottom chord where <br /> there are hvo or more adjacent trusses with the same web configuration capable OF containing a rectangle 42 inches high or greater by 2 feel wide <br /> or greater, located within the plane of the truss. the rectangle shall lit between the top of the bottom chord and the bottom of anw other truss <br /> niember,provided that each of the following criteria is met. <br /> I the attic area is accessible bT a pull-down stairway or framed in accordance with Section 88117.1. <br /> 2 the truss has a bottom chord pitch less than 2'12 <br /> Required insulation depth is less than the bottom chord member depth. the bottom chords of trusses meeting the chose criteria for <br /> limited storage shall he designed lilt the greater of the actual imposed dead load or 10 psi,u111100nh (kg'hilted raver the cnGre span <br /> h (diving used in handrail assemblies and guards shall he designed with a safely factor of 4. the safety factor shall he applied to each of the <br /> concentrated loads applied to the lop of the rail, and to the load on the in-fill contponents. l'hese loads shall he determined independent of one <br /> another,and loads are assumed not to occur with any other live load. <br /> 20.10.060 CRC Section R308.7 added —Shower Enclosures. <br /> Section R308 is amended by adding section R308.7 to read as shown in section 2411 <br /> of the Pleasanton Building Code (PMC Chapter 20.08). <br /> 20.10.070 CRC Section R313 amended— Automatic Fire Sprinkler Systems <br /> Section R313 is deleted in its entirety and amended to read as follows: <br /> R313.1 Automatic Fire Sprinkler Systems. An automatic residential fire sprinkler <br /> system shall be designed and installed in accordance with NFPA 13D in all new one- <br /> and two- family dwellings and townhouses. In addition, the fire-sprinkler system shall <br /> be designed and sprinklers shall be installed in the following locations: <br /> 1. Attic shall be provided with intermediate temperature-rated residential fire <br /> sprinklers for detection coverage, and located at a spacing equivalent to 30 feet <br /> by 30 feet centers and a maximum distance of 15 feet from outside walls. <br /> 2. Fire sprinklers shall be provided in garages. Fire sprinklers shall be intermediate <br /> rated, quick response type, with a maximum coverage area of 130 square feet <br /> per sprinkler. <br /> R313.2 Large One- and Two-Family Dwelling Residential Sprinkler Systems. In <br /> addition to the requirements specified in R313.1, one- and two- family dwellings with a <br /> habitable floor area greater than 7,500 square feet shall have an automatic fire-sprinkler <br /> system designed to include all sprinklers within a compartment, up to a maximum of <br /> four sprinklers. <br /> 20.10.080 CRC Section R314.3.2 added — Smoke Alarm Installation at Time of <br /> Sale or Transfer. <br /> Section R314.3 is amended by adding Section R314.3.2 to read as follows: <br />
The URL can be used to link to this page
Your browser does not support the video tag.