My WebLink
|
Help
|
About
|
Sign Out
03
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2013
>
101513
>
03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2016 2:56:22 PM
Creation date
10/9/2013 4:06:39 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
10/15/2013
DESTRUCT DATE
15Y
DOCUMENT NO
03
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
not be removed before inspection. Three hinges are allowed only when a plumb <br /> substrate is provided. <br /> 2411.3.2 Screws. Stainless steel screws shall be used of minimum size #10 and a <br /> length sufficient to make a minimum penetration into the wood frame of 11/2 inch (38 <br /> mm). This penetration into the substrate shall be sealed with a non-hardening, <br /> asphalt base sealant. <br /> 2411.3.3 Minimum Thickness. Hinged shower doors and stationary panels shall be <br /> a minimum of 3/8 inch (10 mm) tempered glass. <br /> 2411.3.4 Recommended Clearances. Clearance between a door and panel or door <br /> and wall shall be no less than 1/8 inch (3.2 mm). Clearance at the bottom of the door <br /> shall be no less than 3/16 inch (5 mm) between the exposed glass edge and the curb <br /> or threshold. <br /> 2411.4 Size Limitation. <br /> 2411.4.1 Doors. Shower doors shall not exceed 38 inches (965 mm) in width or 150 <br /> lbs. in weight. <br /> Exception: These limits may be exceeded only when a licensed engineer submits <br /> a stamped calculation. <br /> 2411.4.2 Non-load Bearing Panels. 3/8 inch (10 mm) panels may not exceed 110 <br /> (2,794 mm) united inches, width + height (UI). 1/2 inch (12 mm) panels shall not <br /> exceed 120 (3,048 mm) UI, as per AGA SH1. Height limitation, 84 inches <br /> (2,134mm). <br /> Exception: When three sides of the panel are attached to the structure, the UI <br /> limitations may be removed. A transom shall be considered the same as a <br /> header or ceiling mount and shall be secured with channel or clips on 4 sides. <br /> 2411.5 Mechanical Fastening Hardware (metal clips, header, tube bracing or <br /> channels) <br /> 2411.5.1 Metal Clips. U Channels shall be fastened to the finished shower wall. The <br /> only permitted penetration through the finished shower wall shall be the mounting <br /> screws for clips, <br /> channels, and hinges. Reglet design is not recommended. <br /> 2411.5.2 Clip Location. Clips on the long edge of the glass shall be located <br /> between 4 inches (102 mm) and 8 inches 203 mm) from each end of the glass. A <br /> third clip shall be on the long edge if the glass exceeds 48" in length. Clips shall be <br /> centered on the short edge on panels up to 16 inches (406 mm) in width. For greater <br /> widths, two clips shall be used, one at each one-third point. <br /> 2411.5.3 Non-Load Bearing Side Panels. Non-load bearing side panels shall be <br /> mounted by mechanical fasteners on the bottom and the top or bottom and one <br /> vertical side. <br /> Exception: For two in-line side panels (such as a buttress design) and/or to a <br /> return panel, the vertical butt joint(s) shall be sealed with a structural silicone <br /> sealant and shall be secured at the top with a joint spanning clip(s) or header. <br /> 2411.5.4 Load-bearing side panels. Load-bearing side panels and any return panel <br /> shall be secured with mechanical fasteners on three sides. The minimum width of a <br /> load-bearing panel shall be 5 inches (127 mm). <br /> 20.08.170 CBC Chapter 31B adopted and amended — Public Swimming Pools. <br />
The URL can be used to link to this page
Your browser does not support the video tag.