My WebLink
|
Help
|
About
|
Sign Out
ORD 2077
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2001 - 2100
>
ORD 2077
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:02 PM
Creation date
9/17/2013 4:46:50 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
9/3/2013
DESTRUCT DATE
PERMANENT
DOCUMENT NO
ORD 2077
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
133. All building and/or structural plans must comply with all codes and ordinances in <br /> effect before the Building and Safety Division will issue permits. <br /> Livermore-Pleasanton Fire Department <br /> 134. All construction shall conform to the requirements of the California Fire Code <br /> currently in effect, City of Pleasanton Building and Safety Division and City of <br /> Pleasanton Ordinance 2015. All required permits shall be obtained. <br /> 135. Automatic fire sprinklers shall be installed in all occupancies in accordance with <br /> City of Pleasanton Ordinance 2015. Installations shall conform to NFPA <br /> Pamphlet 13 for commercial occupancies NFPA 13D for residential occupancies <br /> and NFPA 13R for multifamily residential occupancies. <br /> 136. Fire alarm system shall be provided and installed in accordance with the CFC <br /> currently in effect, the City of Pleasanton Ordinance 2015 and 2002 NFPA 72 - <br /> National Fire Alarm Code. Notification appliances and manual fire alarm boxes <br /> shall be provided in all areas consistent with the definition of a notification zone <br /> (notification zones coincide with the smoke and fire zones of a building). Shop <br /> drawings shall be submitted for permit issuance in compliance with the CFC <br /> currently in effect. <br /> 137. Underground fire mains, fire hydrants and control valves shall be installed in <br /> conformance with the most recently adopted edition of NFPA Pamphlet 24, <br /> "Outside Protection." <br /> a. The underground pipeline contractor shall submit a minimum of three (3) sets <br /> of installation drawings to the Fire Department, Fire Prevention Bureau. The <br /> plans shall have the contractor's wet stamp indicating the California contractor <br /> license type, license number and must be signed. No underground pipeline <br /> inspections will be conducted prior to issuance of approved plans. <br /> b. All underground fire protection work shall require a California contractor's <br /> license type as follows: C-16, C-34, C-36 or A. <br /> c. All field-testing and inspection of piping joints shall be conducted prior to <br /> covering of any pipeline. <br /> 138. Dead-end fire service water mains shall not exceed 500 feet in length and/or <br /> have more than five Fire Department appliances* shall be looped around the site <br /> or building and have a minimum of two points of water supply or street <br /> connection. Zone valves shall be installed as recommended under NFPA, <br /> Pamphlet 24 and the Fire Marshal. <br /> *Note: Fire Department appliances are classified as fire sprinkler system risers, <br /> fire hydrants and/or standpipes. <br /> 13-Unit)Development Plan Ponderosa Homes <br /> PUD-97, Conditions of Approval 25 of 32 4202 Stanley Boulevard <br />
The URL can be used to link to this page
Your browser does not support the video tag.