My WebLink
|
Help
|
About
|
Sign Out
ORD 2077
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2001 - 2100
>
ORD 2077
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:02 PM
Creation date
9/17/2013 4:46:50 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
9/3/2013
DESTRUCT DATE
PERMANENT
DOCUMENT NO
ORD 2077
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
117. The project developer shall keep the site free of fire hazards from the start of <br /> lumber construction until the final inspection. <br /> 118. Prior to any construction framing, the project developer shall provide adequate <br /> fire protection facilities, including, but not limited to a water supply and water flow <br /> in conformance to the City's Fire Department Standards able to suppress a major <br /> fire. <br /> 119. The Fire Prevention Bureau reviews building/civil drawings for conceptual on-site <br /> fire mains and fire hydrant locations only. Plan check comments and approvals <br /> DO NOT INCLUDE: <br /> a. Installation of the on-site fire mains and fire hydrants. Specific installation <br /> drawings submitted by the licensed underground fire protection contractor <br /> shall be submitted to the Fire Prevention Bureau for approval. <br /> b. Backflow prevention or connections to the public water mains. <br /> 120. Electrical conduit shall be provided to each fire protection system control valve <br /> including all valve(s) at the water connections. The Livermore-Pleasanton Fire <br /> Department requires electronic supervision of all valves for automatic sprinkler <br /> systems and fire protection systems. <br /> 121. Address numbers shall be installed on the front or primary entrance for all <br /> buildings. Minimum building address character size shall be 12" high by 1" <br /> stroke. If building is located greater than 50 feet from street frontage, character <br /> size shall be 16" high by 1 ''/2' stroke minimum. In all cases address numerals <br /> shall be of contrasting background and clearly visible in accordance with the <br /> Livermore-Pleasanton Fire Department Premises Identification Standards. This <br /> may warrant field verification and adjustments based upon topography, <br /> landscaping or other obstructions. <br /> 122. The following items will be provided prior to any construction above the <br /> foundation or slab. NOTE: Periodic inspections will be made for compliance. <br /> a. Emergency vehicle access will be required to be provided to the site (tract), <br /> including the area where construction is occurring. <br /> b. Emergency vehicle access shall be a minimum of 20 feet in clear width. A <br /> clear height free of obstructions (power, cable, telephone lines, tree limbs, <br /> etc.) is required. This clearance shall be a minimum of 13 feet-6 inches. <br /> Inside turning radius of 45 feet and outside turning radius of 55 feet shall be <br /> provided. <br /> c. Buildings or portions of buildings or facilities exceeding 30 feet (9144 mm) in <br /> height above the lowest level of fire department vehicle access shall be <br /> 13-Unit'Development Plan Ponderosa Homes <br /> PUD-97, Conditions of Approval 22 of 32 4202 Stanley Boulevard <br />
The URL can be used to link to this page
Your browser does not support the video tag.