My WebLink
|
Help
|
About
|
Sign Out
ORD 2071
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2001 - 2100
>
ORD 2071
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:02 PM
Creation date
9/17/2013 4:45:11 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
6/18/2013
DESTRUCT DATE
PERMANENT
DOCUMENT NO
ORD 2071
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(notification zones coincide with the smoke and fire zones of a building). Shop <br /> drawings shall be submitted for permit issuance in compliance with the CFC <br /> currently in effect. <br /> 132. City of Pleasanton Ordinance 2015 requires that all new and existing occupancies <br /> be provided with an approved key box from the Knox Company as specified by the <br /> Fire Department. The applicant/developer is responsible for obtaining approval for <br /> the location and the number of boxes from the Fire Prevention Bureau. Information <br /> and application for the Knox Box is available through their website or the Fire <br /> Prevention Bureau. The applicant/developer and/or responsible party shall be <br /> responsible for providing tenant space building access keys for insertion into the <br /> Knox Box prior to final inspection by the Fire Department. Keys shall have <br /> permanent marked tags identifying address and/or specific doors/areas accessible <br /> with said key. <br /> 133. Underground fire mains, fire hydrants and control valves shall be installed in <br /> conformance with the most recently adopted edition of NFPA Pamphlet 24, <br /> "Outside Protection." <br /> • The underground pipeline contractor shall submit a minimum of three (3) sets of <br /> installation drawings to the Fire Department Fire Prevention Bureau. The plans <br /> shall have the contractor's wet stamp indicating the California contractor license <br /> type and license number and must be signed. No underground pipeline <br /> inspections will be conducted prior to issuance of approved plans. <br /> • All underground fire protection work shall require a California contractor's <br /> license type as follows: C-16, C-34, C-36 or A. <br /> • All field-testing and inspection of piping joints shall be conducted prior to <br /> covering of any pipeline. <br /> 134. Dead-end fire service water mains shall not exceed 500 feet in length and/or have <br /> more than five Fire Department appliances* shall be looped around the site or <br /> building and have a minimum of two points of water supply or street connection. <br /> Zone valves shall be installed as recommended under NFPA, Pamphlet 24 and the <br /> Fire Marshal. <br /> *Note: Fire Department appliances are classified as fire sprinkler system <br /> risers, fire hydrants, and/or standpipes. <br /> 135. Portable fire extinguisher(s) shall be provided and installed in accordance with the <br /> California Fire Code currently in effect and Fire Code Standard #10-1. Minimum <br /> approved size for all portable fire extinguishers shall be 2A 10B:C. <br /> 136. All buildings undergoing construction, alteration or demolition shall comply with <br /> Chapter 14 (California Fire Code currently in effect) pertaining to the use of any <br /> hazardous materials, flame-producing devices, asphalt/tar kettles, etc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.