118. Electrical conduit shall be provided to each fire protection system control valve <br /> including all valve(s) at the water connections. The Livermore-Pleasanton Fire <br /> Department requires electronic supervision of all valves for automatic sprinkler <br /> systems and fire protection systems. <br /> 119. Address numbers shall be installed on the front or primary entrance for all buildings. <br /> Minimum building address character size shall be 12" high by 1" stroke. For <br /> buildings located greater than 50 feet from street frontage, the character size shall <br /> be 16" high by 1 ''/z" stroke minimum. Where multiple access is provided, address or <br /> tenant space numbers shall be provided on each access door and the character <br /> size shall be no less than 4" high by % " stroke. In all cases, address numerals shall <br /> be of contrasting background and clearly visible in accordance with the Livermore- <br /> Pleasanton Fire Department Premises Identification Standards. This may warrant <br /> field verification and adjustments based upon topography, landscaping, or other <br /> obstructions. <br /> 120. The following items will be provided prior to any construction above the foundation <br /> or slab. NOTE: Periodic inspections will be made for compliance. <br /> a. Emergency vehicle access shall be provided to the site, including the area <br /> where construction is occurring. If Public Works improvements are part of the <br /> project to access the site, an emergency vehicle access plan shall be <br /> submitted for review and approval. <br /> b. Multi-family residential developments: Projects having more than 100 dwelling <br /> units shall be equipped throughout with two separate and approved fire <br /> apparatus access roads. <br /> c. Emergency vehicle access shall be a minimum of 20 feet in clear width. A <br /> clear height free of obstructions (power, cable, telephone lines, tree limbs, <br /> etc.) is required. This clearance shall be a minimum of 13-feet, 6-inches. <br /> Inside turning radius of 45 feet and outside turning radius of 55 feet shall be <br /> provided. <br /> d. The carrying capacity of the access route(s) shall be 69,000 pounds under all <br /> weather conditions. <br /> e. Designated construction material storage and construction worker parking <br /> shall not obstruct the emergency vehicle access route(s). <br /> f. On-site fire hydrants shall be in service. Fire hydrants shall be flushed and all <br /> valves open. <br />