My WebLink
|
Help
|
About
|
Sign Out
06
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2013
>
091713
>
06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2013 12:21:35 PM
Creation date
9/12/2013 3:38:58 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
9/17/2013
DESTRUCT DATE
15Y
DOCUMENT NO
06
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1613.8 ASCE 7, Section 12.8.7. Modify ASCE 7, Section 12.8.7 by amending Equation <br />12.8 -16 as follows: <br />9 = Px A 1 (12.8 -16) <br />Vxh,,Cd <br />20.08.090 CBC Section 1704.4 amended - Concrete Construction. <br />Section 1704.4 is amended to read as follows: <br />1704.4 Concrete Construction. The special inspections and verifications for concrete <br />construction shall be as required by this section and Table 1704.4. <br />Exceptions: Special inspections shall not be required for isolated spread concrete <br />footings of buildings three stories or less above grade plane that are fully supported <br />on earth or rock, where the structural design of the footing is based on a specified <br />compressive strength, f'c, no greater than 2,500 pound per square inch (psi) (17.2 <br />Mpa). <br />20.08.100 CBC Section 1809.8 amended — Plain concrete footings. <br />Section 1809.8 is amended to read as follows: <br />1806.1 Plain concrete footings. The edge thickness of plain concrete footings <br />supporting walls of other than light -frame construction shall not be less than 8 inches <br />(203mm) where placed on soil and in all cases, as a minimum, one '/2" (51 mm) <br />continuous rebar shall be placed at the top and at the bottom of all grade beams and <br />spread footings. <br />Exception: For plain concrete footings supporting Groups R -3 and one story Group <br />U occupancies the edge thickness is permitted to be 6 inches (152mm), provided <br />that the footing does not extend beyond a distance greater than the thickness of the <br />footing on either side of the supported wall. In all cases, as a minimum, one ' /z" <br />(51 mm) continuous rebar shall be placed at the top and at the bottom of all grade <br />beams and spread footings. <br />20.08.110 CBC Section 1905.8 amended - ACI 318 section 22.10.1. <br />Section 1905.8 is amended to read as follows: <br />1905.8 ACI 318, section 22.10. Delete ACI 318, section 22.10, and replace with the <br />following: <br />
The URL can be used to link to this page
Your browser does not support the video tag.