7.2. The gate and barrier shall have no opening larger than 1/2 inch (12.7 mm) <br />within 18 inches (457 mm) of the release mechanism. <br />8. Where a wall of a dwelling serves as part of the barrier, one of the following <br />conditions shall be met: <br />8.1. The pool shall be equipped with an approved powered safety cover in <br />compliance with ASTM F 1346; or <br />8.2. Doors with direct access to the pool through that wall shall be equipped with <br />an alarm which produces an audible warning when the door and /or its <br />screen, if present, are opened. The alarm shall be listed and labeled in <br />accordance with UL 2017. The deactivation switch(es) shall be located at <br />least 54 inches (1372 mm) above the threshold of the door; or <br />8.3. Other means of protection, such as self - closing doors with self - latching <br />devices, which are approved by the governing body, shall be acceptable as <br />long as the degree of protection afforded is not less than the protection <br />afforded by Item 8.1 or 8.2 described above. <br />9. Where an above - ground pool structure is used as a barrier or where the barrier is <br />mounted on top of the pool structure, and the means of access is a ladder or <br />steps: <br />9.1. The ladder or steps shall be capable of being secured, locked or removed to <br />prevent access; or <br />9.2. The ladder or steps shall be surrounded by a barrier which meets the <br />requirements of Section AG105.2, Items 1 through 8. When the ladder or <br />steps are secured, locked or removed, any opening created shall not allow <br />the passage of a 4- inch - diameter (102 mm) sphere. <br />Prior to the issuance of any final approval for the completion of permitted construction or <br />remodeling work, the Building and Safety Official shall inspect and verify the drowning <br />safety prevention devices required have been installed and functional properly. <br />AG105.3 Indoor swimming pool. Walls surrounding an indoor swimming pool shall <br />comply with Section AG 105.2, Item 8. <br />AG105.4 Prohibited locations. Barriers shall be located to prohibit permanent <br />structures, equipment or similar objects from being used to climb them. <br />AG105.5 Barriers. <br />AG105.5.1 Enclosure; required characteristics. An enclosure shall have all of the <br />following characteristics: <br />1. Any access gates through the enclosure open away from the swimming pool and <br />are self - closing with a self - latching device placed no lower than 60 inches (1524 <br />mm) above the ground. <br />2. A minimum height of 60 inches (1524 mm). <br />3. A maximum vertical clearance from the ground to the bottom of the enclosure of <br />2 inches (51 mm). <br />4. Gaps or voids, if any, do not allow passage of a sphere equal to or greater than 4 <br />inches (102 mm) in diameter. <br />
The URL can be used to link to this page
Your browser does not support the video tag.