My WebLink
|
Help
|
About
|
Sign Out
14
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2013
>
090313
>
14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2013 12:48:15 PM
Creation date
8/29/2013 12:47:47 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
9/3/2013
DESTRUCT DATE
15Y
DOCUMENT NO
14
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
141. Address numbers shall be installed on the front or primary entrance for all buildings. <br /> Minimum building address character size shall be minimum 4 inches high by a '/-inch <br /> stroke. <br /> 142. The private courts shall be designated as fire lanes and identified as such by red curb <br /> striping and posted with signs on both sides of the street at locations approved by the <br /> Fire Department. Signs shall be according to State of California standards and shall <br /> read, "No Parking - Fire Lane." The signs and curbs shall be shown on the improvement <br /> plans to the satisfaction of the City Engineer and the Directo- of Community <br /> Development. <br /> 143. The buildings covered by this approval shall be equipped with an automatic fire sprinkler <br /> system. Plans and specifications for the automatic fire sprinkler system shall be <br /> submitted for review and approval by the Livermore-Pleasanton Fire Department prior to <br /> installation. The fire alarm system, including water flow and valve tamper, shall have <br /> shop drawings submitted for review and approval by the Livermore-Pleasanton Fire <br /> Department prior to installation. All required inspections and witnessing of tests shall be <br /> completed prior to final inspection and occupancy of the building(s). <br /> 144. Valve tamper and water flow shall be monitored by an approved supervising station in <br /> accordance with NFPA 72 and the California Fire Code. <br /> STANDARD CONDITIONS OF APPROVAL <br /> Fire <br /> 145. The apartments shall have valve tamper and water flow connected to an Underwriters <br /> Laboratory (UL) listed Central Station Service. Fire Department plan check includes <br /> specifications, monitoring certificate(s), installation certificate and alarm company UL <br /> certificate. <br /> 146. The project applicant/developer shall keep the site free of fire hazards from the start of <br /> lumber construction until the final inspection. <br /> 147. Fire alarm control panel and remote annunciation shall be at location(s; approved by the <br /> Fire Prevention Bureau. All systems shall be point identified by indi,idual device and <br /> annunciated by device type and point. <br /> 148. All fire sprinkler system water flow and control valves shall be complete and serviceable <br /> prior to final inspection. Prior to the occupancy of a building having a f re alarm system, <br /> the Fire Department shall test and witness the operation of the fire alarm system. <br /> 149. Prior to any construction framing, the project applicant/developer shall provide adequate <br /> fire protection facilities, including, but not limited to a water supply and water flow in <br /> conformance to the City's Fire Department Standards able to suppress a major fire. <br /> 150. All fire sprinkler system water flow and control valves shall be complete and serviceable <br /> prior to final inspection. Prior to the occupancy of a building having a f re alarm system, <br /> the Fire Department shall test and witness the operation of the fire alarm system. <br /> Page 28 <br />
The URL can be used to link to this page
Your browser does not support the video tag.