Laserfiche WebLink
133. The buildings covered by this approval shall be designed and constructed to <br /> meet Title 24 state energy requirements. <br /> 134. All building and/or structural plans must comply with all codes aid ordinances in <br /> effect before the Building and Safety Division will issue permits. <br /> Livermore-Pleasanton Fire Department <br /> 135. All construction shall conform to the requirements of the California Fire Code <br /> currently in effect, City of Pleasanton Building and Safety Division and City of <br /> Pleasanton Ordinance 2015. All required permits shall be obtained. <br /> 136. Automatic fire sprinklers shall be installed in all occupancies in accordance with <br /> City of Pleasanton Ordinance 2015. Installations shall conform to NFPA <br /> Pamphlet 13 for commercial occupancies NFPA 13D for residential occupancies <br /> and NFPA 13R for multifamily residential occupancies. <br /> 137. Fire alarm system shall be provided and installed in accordance with the CFC <br /> currently in effect, the City of Pleasanton Ordinance 2015 and 2002 NFPA 72 - <br /> National Fire Alarm Code. Notification appliances and manual fire alarm boxes <br /> shall be provided in all areas consistent with the definition of a notification zone <br /> (notification zones coincide with the smoke and fire zones of E. building). Shop <br /> drawings shall be submitted for permit issuance in compliance with the CFC <br /> currently in effect. <br /> 138. Underground fire mains, fire hydrants and control valves shall be installed in <br /> conformance with the most recently adopted edition of NFP4 Pamphlet 24, <br /> "Outside Protection." <br /> a. The underground pipeline contractor shall submit a minimum of three (3) sets <br /> of installation drawings to the Fire Department, Fire Prevention Bureau. The <br /> plans shall have the contractor's wet stamp indicating the California contractor <br /> license type, license number and must be signed. No underground pipeline <br /> inspections will be conducted prior to issuance of approved plans. <br /> b. All underground fire protection work shall require a California contractor's <br /> license type as follows: C-16, C-34, C-36 or A. <br /> c. All field-testing and inspection of piping joints shall be conducted prior to <br /> covering of any pipeline. <br /> 139. Dead-end fire service water mains shall not exceed 500 feet in length and/or <br /> have more than five Fire Department appliances* shall be looped around the site <br /> or building and have a minimum of two points of water supply or street <br /> 13-Unitl Development Plan Ponderosa Homes <br /> PUD-97, Conditions of Approval 25 of 32 4262 Stanley Boulevard <br />