My WebLink
|
Help
|
About
|
Sign Out
17
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2013
>
082013
>
17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2013 12:31:08 PM
Creation date
8/14/2013 2:25:49 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
8/20/2013
DESTRUCT DATE
15Y
DOCUMENT NO
17
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
install new services to the units within the proposed developmeit underground, <br /> in conduit, to the nearest "utility approved" riser pole. <br /> 59. The applicant shall be required to pay its pro-rata share, at the rate of $1,065.34 <br /> per linear foot, for undergrounding of the overhead utility lines across the project <br /> frontage, including the service lines to the proposed development. Said payment <br /> will be required to the City prior to approval of a final map. <br /> 60. Should the applicant's project precede the development located at 4171 and <br /> 4189 Stanley Boulevard and the City's CIP on Stanley Boulevard, the applicant <br /> shall be required to install a storm drain pipe in Stanley Boulevard to Main Street. <br /> Should the CIP for Stanley Boulevard precede the approval of the applicant's <br /> final map, the applicant shall be required to pay its pro-rata share of the storm <br /> drain line to serve the proposed development. <br /> 61. All enhanced landscaping, as determined by the City Operation Service Center, <br /> within public right-of-way shall be maintained by the project's homeowners <br /> association with onsite irrigation water. <br /> 62. All landscaping within public right-of-way along the project's frontage shall be <br /> maintained by the homeowners association unless otherwise approved by the <br /> City Engineer and necessary irrigation system, irrigation water meter, irrigation <br /> valves, irrigation controller, etc. have been included on the plan .:or maintenance <br /> of all landscaping within public right-of-way. <br /> 63. The bio-swales and hydro-modification areas next to the proposed sidewalk shall <br /> have a retaining wall and sub drains as required by the City Engineer. Said walls <br /> and sub drains shall be shown on the plans submitted to the Bui ding and Safety <br /> Division for plan check and subject to the review and approval of the City <br /> Engineer prior to issuance of a building permit. <br /> 64. A geologic report shall be prepared as per City Municipal Code 17.12 Geologic <br /> Hazard, 18.68 PUD District, and as required by the City Engineer for site specific <br /> conditions. <br /> 65. For new streets, the minimum grade for the gutter flow line shall be set at one <br /> percent where practical, but not less than .75% unless otherwise approved by the <br /> City Engineer. <br /> Operation Services Center <br /> 66. A backflow prevention device shall be required to isolate the public water main <br /> from the private main. The backflow device shall be shows on the plans <br /> submitted to the Building and Safety Division for plan check and shall be subject <br /> to the review and approval of the City Engineer prior to issuance of a building <br /> permit. <br /> 14-Unit Development Plan Ponderosa Homes <br /> PUD-97, Conditions of Approval 12 of 31 420;? Stanley Boulevard <br />
The URL can be used to link to this page
Your browser does not support the video tag.