Laserfiche WebLink
b. Multi-family residential developments: Projects having more than 100 dwelling <br /> units shall be equipped throughout with two separate and approved fire <br /> apparatus access roads. <br /> c. Emergency vehicle access shall be a minimum of 20 feet in clear width. A <br /> clear height free of obstructions (power, cable, telephone lines, tree limbs, <br /> etc.) is required. This clearance shall be a minimum of 1:3-feet, 6-inches. <br /> Inside turning radius of 45 feet and outside turning radius of 55 feet shall be <br /> provided. <br /> d. The carrying capacity of the access route(s) shall be 69,000 pounds under all <br /> weather conditions. <br /> e. Designated construction material storage and construction worker parking <br /> shall not obstruct the emergency vehicle access route(s). <br /> f. On-site fire hydrants shall be in service. Fire hydrants shall be flushed and all <br /> valves open. <br /> g. On-site fire hydrants shall not be obstructed and shall be sufficiently above <br /> grade to have all hydrant valves and outlets accessible for emergency use. <br /> h. Where a project is phased as part of the development approved by the City, <br /> specific access, water supply and fire hydrant installations wi!II be required as <br /> part of each phase. As needed a phasing plan with these improvements will <br /> be required. <br /> i. Where on-site grading/utility plans are submitted for review arid approval prior <br /> to building construction drawings, emergency vehicle access routes, fire <br /> hydrant locations, material staging areas, etc. shall be provided. <br /> Community Development Department <br /> 146. The project applicant/developer shall submit a refundable cash bond for hazard <br /> and erosion control. The amount of this bond will be determined by the Director of <br /> Community Development. The cash bond will be retained by the City until all the <br /> permanent landscaping is installed for the development, including individual lots, <br /> unless otherwise approved by the department. <br /> 147. The project developer shall submit a written dust control plan or procedure as part <br /> of the building permit plans. <br /> 148. If any prehistoric or historic artifacts, or other indication of cultural resources are <br /> found once the project construction is underway, all work must stop within 20 <br /> meters (66 feet) of the find. A qualified archaeologist shall be consulted for an <br /> immediate evaluation of the find prior to resuming groundbreaking construction <br /> activities within 20 meters of the find. If the find is determined to be an important <br /> archaeological resource, the resource shall be either avoided, if feasible, or <br /> recovered consistent with the requirements of Appendix K of the State CEQA <br /> Guidelines. In the event of discovery or recognition of any human remains in any <br /> on-site location, there shall be no further excavation or disturbance of the site or <br /> any nearby area reasonably suspected to overlie adjacent remains until the <br /> County coroner has determined, in accordance with any law concerning <br /> investigation of the circumstances, the manner and cause of death and has made <br /> 25 of 34 <br />