My WebLink
|
Help
|
About
|
Sign Out
03
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2011
>
120611
>
03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2011 4:02:55 PM
Creation date
11/30/2011 3:15:58 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
12/6/2011
DESTRUCT DATE
15Y
DOCUMENT NO
03
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Director of Community Development, or shall be an approved crib wall type. Calculations <br /> signed by a registered civil engineer shall accompany the wall plans. <br /> 76. At the time of building permit plan submittal, the project applicant shall submit a final grading <br /> and drainage plan prepared by a licensed civil engineer depicting all final grades and on-site <br /> drainage control measures to prevent stormwater runoff onto adjoining properties. <br /> Fire <br /> 77. The project applicant shall keep the site free of fire hazards from the start of lumber <br /> construction until the final inspection. <br /> 78. Prior to any construction framing, the project applicant shall provide adequate fire protection <br /> facilities, including, but not limited to a water supply and water flow in conformance to the <br /> City's Fire Department Standards able to suppress a major fire. <br /> 79. Electrical conduit shall be provided to each fire protection system control valve including all <br /> valve(s) at the water connections. The Livermore-Pleasanton Fire Department requires <br /> electronic supervision of all valves for automatic sprinkler systems and fire protection <br /> systems. <br /> 80. All curbs located with a seven-foot, six-inch radius of a public/private fire hydrant shall be <br /> painted red, unless, modified by the Fire Chief. Blue street "hydrant markers" shall be <br /> installed for all fire hydrants per City of Pleasanton Standard Specifications. <br /> 81. All driveway aisles designated as fire lanes by the Fire Chief shall be maintained in <br /> accordance with Articles 9 and 10 of the Uniform Fire Code, which permits towing vehicles <br /> illegally parked on the fire lanes. Fire lane curbs shall be painted red with "No Parking, Fire <br /> Lane, Tow Away Zone" in white lettering on the curb, or shall be signed, "No Parking, Fire <br /> Lane, Tow Away Zone", as required by the California Vehicle Code. <br /> 82. A permit issued by the Fire Chief is required prior to any installation of a fire detection, alarm, <br /> and occupant notification system. All sprinkler system water flow and control valves shall be <br /> complete and serviceable prior to final inspection. Prior to the occupancy of a building having <br /> a fire alarm system, the Fire Department shall test and witness the operation of the fire alarm <br /> system. <br /> 83. All portions of the building covered by this approval shall have installed and operating, fire <br /> extinguishers with a minimum 2-A:10-B:C rating. The fire extinguishers shall be located <br /> within a 75-foot radius of each other. <br /> URBAN STORMWATER CONDITIONS OF APPROVAL <br /> 84. The project shall comply with the "Alameda Countywide NPDES Permit #CAS0029831 and <br /> amendments to this permit" issued the by California Regional Water Quality Control Board, <br /> San Francisco Bay Region, a copy of which is available at the Community Development <br /> Department, Public Works/Engineering section at City offices, Alameda County Clean Water <br /> Program and at State Water Board. <br /> (http://www.waterboard s.ca.g ov/sa nfran cisco bay/boa rd_i n fo/age n das/2003/fe bru a <br /> ry/02-19-03-12fina Ito.doc <br /> and <br /> http://www.waterboards.ca.gov/sanfranciscobay/board_i nfo/agendas/2007/march/ <br /> aameda%20fi nal%20order%20r2-2007-0025.pdf) <br /> 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.