My WebLink
|
Help
|
About
|
Sign Out
03
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2011
>
111511
>
03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2011 3:17:17 PM
Creation date
11/9/2011 12:04:24 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
11/15/2011
DESTRUCT DATE
15Y
DOCUMENT NO
03
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
control panel and remote annunciation shall be at location(s) approved by the Fire <br /> Prevention Bureau. All systems shall be point identified by individual device and <br /> annunciated by device type and point. <br /> 91.Electrical conduit shall be provided to each fire protection system control valve <br /> including all valve(s) at the water connections. The Livermore-Pleasanton Fire <br /> Department requires electronic supervision of all valves for automatic sprinkler <br /> systems and fire protection systems. <br /> 92.The following items will be provided prior to any construction above the foundation or <br /> slab. NOTE: Periodic inspections will be made for compliance. <br /> a. Emergency vehicle access shall be provided to the site. If Public Works <br /> Improvements are part of the project to access the site, an emergency vehicle <br /> access plan shall be submitted for review and approval. <br /> b. Site access shall be provided prior to any construction above the foundation <br /> or slab. Based on the Site Plan Approval the access shall be installed. <br /> c. Emergency vehicle access shall be a minimum of 20 feet in width. A clear <br /> height free of obstructions (power, cable, telephone lines, tree limbs, etc.) <br /> shall be provided. This clearance shall be a minimum of 13 feet-6 inches. <br /> Inside turning radius of 45 feet and outside turning radius of 55 feet shall be <br /> provided. <br /> d. Where on-site fire hydrant(s) are required, they shall be installed, flushed and <br /> all valves open prior to any construction above the foundation or slab. This <br /> includes concrete tilt-up and masonry buildings. <br /> e. On-site fire hydrant(s) shall not be obstructed and shall be sufficiently above <br /> grade to have all hydrant valves and outlets accessible for emergency use. <br /> j. Prior to request for final inspection, all access roads, on-site access and fire <br /> hydrants shall be provided. All fire hydrants shall be acceptance inspected <br /> and tested to applicable City Public Works Standards. <br /> LANDSCAPING <br /> 93.The project developer shall enter into an agreement with the City, approved by the <br /> City Attorney, which guarantees that all landscaping and open space areas included <br /> in this project will be maintained at all times in a manner consistent with the <br /> approved landscape plan for this development. Said agreement shall run with the <br /> land for the duration of the existence of the structures located on the subject <br /> property. <br /> 94.Six-inch vertical concrete curbs shall be installed between all paved and landscaped <br /> areas. <br /> Page 13 of 21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.