My WebLink
|
Help
|
About
|
Sign Out
ORD 2021
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2001 - 2100
>
ORD 2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:02 PM
Creation date
10/27/2011 12:17:56 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/18/2011
DESTRUCT DATE
PERMANENT
DOCUMENT NO
ORD 2021
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
approved plans. All underground fire protection work shall require a California contractor's <br /> license type as follows: C-16, C-34, C-36 or A. <br /> • All field-testing and inspection of piping joints shall be conducted prior to covering of any <br /> pipeline. <br /> 124. All buildings undergoing construction, alteration or demolition shall comply with Chapter 14 <br /> (2010 California Fire Code) pertaining to the use of any hazardous materials, flame- producing <br /> devices, asphalt/tar kettles, etc. <br /> 125. Dead-end fire service water mains shall not exceed 500 feet in length and/or have more than <br /> five Fire Department appliances* shall be looped around the site or building and have a <br /> minimum of two points of water supply or street connection. Zone valves shall be installed as <br /> recommended under NFPA, Pamphlet 24 and the Fire Marshal. <br /> * Note: Fire Department appliances are classified as fire sprinkler system risers, fire hydrants, <br /> and/or standpipes. <br /> 126. The building(s) covered by this approval shall conform to the requirements of the California <br /> Building Code currently in effect, California Fire Code currently in effect, and City of Pleasanton <br /> Ordinance #2015. If required, plans and specifications for the automatic fire sprinkler system <br /> shall be submitted to the Livermore-Pleasanton Fire Department for review and approval prior to <br /> installation. The fire alarm system, including water flow and valve tamper, shall have plans and <br /> specifications submitted to Fire Prevention for review and approval prior to installation. All <br /> required inspections and witnessing of tests shall be completed prior to final inspection and <br /> occupancy of the building(s). <br /> STANDARD URBAN STORMWATER CONDITIONS OF APPROVAL <br /> The project shall comply with the California Regional Water Quality Control Board, San <br /> Francisco Bay Region, Municipal Regional Stormwater NPDES Permit, Order R2-2009-0074, <br /> NPDES Permit No. CAS612008, October 14, 2009: <br /> (http://www.waterboards.ca.qov/sanfranciscobav/board info/agendas/2003/february/02-19-03- <br /> 12finalto.doc.; <br /> and: <br /> http://www.waterboards.ca.gov/sanfranciscobay/board_info/agendas/2007/march/alameda%20fi <br /> nal%20order%20r2-2007-0025.pdf) <br /> The project shall also comply with the "Construction General Permit" by the California Regional <br /> Water Quality Control Board, San Francisco Bay Region: <br /> (http://www.waterboards.ca.qov/water issues/programs/stormwater/construction.shtml) <br /> Design Requirements <br /> 127. The Permit design requirements include, but are not limited to, the following: <br /> a) Source control, sight design measures, and design and implementation of stormwater <br /> treatment measures are required when commercial, industrial, or residential development <br /> 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.