Laserfiche WebLink
addition, a sidewalk would require the removal of a substantial portion of the front yard <br /> landscaping, some of which is being used for stormwater treatment. <br /> Parking <br /> Two garage parking spaces would be provided per unit. In addition, residential driveways <br /> would be at least 18-feet long to accommodate parked vehicles in front of the garage. Five guest <br /> parking spaces would be shared by the development. Currently, general public parking is <br /> allowed on both sides of Stanley Boulevard as long as vehicles are parked off of the pavement. <br /> As part of the Stanley Boulevard reconstruction project, a paved parallel parking lane will be <br /> provided on the north side of the street with no parking allowed on the south side of Stanley <br /> Boulevard. <br /> Since there would be no on-street parking within the development, staff believes it is important <br /> to provide guest parking, and the applicant has provided five spaces. Staff believes the five <br /> guest spaces should be adequate for the project provided that the garages are not modified by the <br /> residents or used for storage in a manner that would interfere with the ability to park two cars <br /> within the garage, that residents park their vehicles in the garages, and that the driveways are <br /> free of boats, trailers, campers, etc. to provide additional parking for guests and any additional <br /> vehicles owned by the residents. A condition of approval requires that the parking restrictions <br /> be recorded as restrictive covenants that will "run with the land" and be binding on all future <br /> property owners. With this condition, staff believes that there would be adequate parking <br /> provided in the development for both residents and guests. <br /> Noise and Vibration <br /> External noise sources that could affect the site include noise from the railroad to the north and <br /> traffic on Stanley Boulevard to the south. For single-family housing projects, the City's General <br /> Plan generally requires that private yard areas excluding front yards not exceed 60 day/night <br /> average decibels (dB Lda) and that indoor noise levels not exceed 45 dB Lin. In addition, if the <br /> noise source is railroad, an exterior noise level up to 70 dB Ldn is allowed and indoor noise <br /> levels cannot exceed a maximum instantaneous noise level (L,,,ax) of 50 dB in bedrooms and 55 <br /> dB in other rooms. A noise study was prepared to ensure that the project will meet General Plan <br /> noise standards. <br /> In order to meet the General Plan noise standards, the noise study indicates the following <br /> mitigation is required: <br /> • Install an 8-ft. tall acoustically effective barrier along the rear property lines of Lots 5, 6, 7, <br /> and 9 and along the rear and eastern side property lines of Lot 8. The applicant is proposing <br /> to install an 8-ft. tall precast concrete soundwall at these locations (see the fencing exhibit, <br /> Sheet L2, for the proposed design). Staff notes that the soundwall heights on the fencing <br /> exhibit need to be modified to conform to the height requirements of the noise study. A <br /> PUD-82 Page - 14 - September 15, 2010 <br />