Laserfiche WebLink
Blocked ` 4/16' <br /> Blocked 4/12' <br /> Blocked ` 8/12' <br /> Blocked ` 6/12 f <br /> 7 <br /> a 6d cooler (1- x 0.092 ") or <br /> Unblocked 4 Wallboard 0.120" nail, min. 3 /8' <br /> head, 1- long <br /> No. 16 gage galv. staple, 1-1" <br /> Blocked " 4 legs, 1- long <br /> Base ply -6d cooler (1- /a xx <br /> 0.092 ") or wallboard 13/ x <br /> 0.120" nail, min. /8" head 1- 5 /8' <br /> 5 f „ 16 gage gale. Staple 1- 16 <br /> 8 gage galv. staple <br /> Blocked ` Base ply: 9 <br /> Two -ply Face ply: 7 Face ply -8d cooler (2- /8 x <br /> 0.113 ") or wallboard 0.120" nail, <br /> min. 3 /g" head, 2- /8" long <br /> No. 15 gage gals. staple, 244" <br /> long <br /> Unblocked 8/12" <br /> Blocked <br /> 8/12 " No. 6 -144" screws <br /> For 61 1 inch = 25 4 mm, 1 foot = 304.8 mm, 1 pounc per foot = 14.5939 N /m. <br /> a. Applies to fastening at studs, tap and bottom plates and blocking. <br /> b. Alternate fasteners are permitted to be used if their dimensions are not less than the specified dimensions. Drywall screws are permitted to substitute for the 5d (1 -5/8 "' <br /> x 0086 "), and 6d (1 -7 /8" x 0 092 ")(cooler) nails 119 e above, and No. 6 1-1/4", inch Type S or W screws for 6d (1 -7/8" x 0.092 ") (cooler) nails. <br /> c. For properties of cooler nails, see ASTM C 514. <br /> d Maximum framing spacing of 24 inches on center <br /> e. All edges are blocked, and edge fastening Is provided at all supports and all panel edges. <br /> f. First number denotes fastener spacing at the edges, second number denotes fastener spacing at intermediate framing members. <br /> g. Screws are Type W or S. <br /> h. Staples shall have a minimum crown width of 7/16 Inch, measured outside the legs, and shall be Installed with their crowns parallel to the long dimension of the framing <br /> members <br /> I. Staples for the attachment of gypsum lath and wcven -wire lath shall have a minimum crown width of 3/4 Inch, measured outside the legs. <br /> 20.08.140 CBC Section 2308.12.4 amended — Braced wall line sheathing. <br /> Section 2308.12.4 is amended to read as follows: <br /> 2308.12.4 Braced wall line sheathing. Braced wall lines shall be braced by one of the <br /> types of sheathing prescribed by Table 2308.12.4 as shown in Figure 2308.9.3. The <br /> sum of lengths of braced wall panels at each braced wall line shall conform to Table <br /> 2308.12.4. Braced wall panels shall be distributed along the length of the braced wall <br /> line and start at not more than 8 feet (2438mm) from each end of the braced wall line. <br /> Panel sheathing joints shall occur over studs or blocking. Sheathing shall be fastened <br /> to studs, top and bottom plates and at panel edges occurring over blocking. Wall <br /> framing to which sheathing used for bracing is applied shall be nominal 2 inch wide [1 <br /> inch (38 mm)] or large mernbers. <br /> Braced wall panel construction types shall not be mixed within a braced wall line. <br /> Braced wall panels required by Section 2308.12.4 may be eliminated when all of the <br /> following requirements are met: <br /> 1. For one story detached garage Group U occupancies not more than 25 feet in <br /> depth or length. <br /> 37 <br />