My WebLink
|
Help
|
About
|
Sign Out
PC 2002-41
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2000-2009
>
2002
>
PC 2002-41
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2007 4:49:07 PM
Creation date
4/16/2003 8:11:35 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
7/10/2002
DOCUMENT NO
PC 2002-41
DOCUMENT NAME
PUD-14
NOTES
GHC INVESTMENTS, LLC
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Building and Site Desi¢n Requirements <br />23. The project developer shall implement the "green building measures" <br />listed under the "Heinz Project -New Home Green Builders Checklist," <br />dated 4-8-02, with the design and construction of all of the homes covered <br />by this approval. <br />a. The proposed measures shall be modified to: <br />(1) meet a minimum job site construction and demolition waste <br />target of 50%; <br />(2) incorporate the photovoltaic option measures included in <br />Conditions 24 and 25. <br />b. The project developer may modify the green building measures, <br />e.g., add new measures, or change existing measures if there are <br />other, more effective measures, which can feasibly be done. <br />Specifically, the developer shall explore the feasibility of using the <br />"Night Breeze" program within this project, or, alternatively, <br />portions of it. The developer is encouraged to incorporate as much <br />of this program as feasible or presently available, such as a whole <br />house fan. <br />c. The project developer shall work with City staff to prepaze a <br />summary report of the effectiveness of implementing the selected <br />components, including as feasible, the costs and benefits of each <br />component. This report shall be prepazed following construction <br />of seventy-five percent (75%) of the project units, with actual <br />energy use data from occupied units, if possible, which shall be <br />forwarded to the Planning Commission for its review. <br />d. The developer shall offer a whole house fan as an option to buyers <br />on all the homes. <br />24. The project developer shall provide to the buyers of the houses covered by <br />this approval photovoltaic systems as an option. With the building permit <br />plan set, the project developer shall show the installations for each of the <br />buildings covered by this approval to the satisfaction of the Planning <br />Developer before issuance of a building permit. <br />25. The project developer shall implement the following measures with the <br />construction of the structures covered by this approval so that the owners <br />can install roof-mounted photovoltaic systems in the future: <br />a. Electrical conduit and cable shall be installed from the roof/attic <br />areas to the buildings' main electrical panels. <br />b. Roof trusses shall be "engineered" to handle an additional load as <br />determined by a structural engineer to accommodate the additional <br />weight of a prototypical photovoltaic system beyond that <br />anticipated for roofing. <br />Conditions of Approval Page 12 of 28 8/2/02 <br />Greenbriaz Homes (PUD-14) <br />