Laserfiche WebLink
steps are secured, locked or removed, any opening created shall not allow <br /> the passage of a 4- inch - diameter (102 mm) sphere. <br /> Prior to the issuance of any final approval for the completion of permitted construction or <br /> remodeling work, the Building and Safety Official shall inspect and verify the drowning <br /> safety prevention devices required have been installed and functional properly. <br /> AG105.3 Indoor swimming pool. Walls surrounding an indoor swimming pool shall <br /> comply with Section AG105 2, Item 8. <br /> AG105.4 Prohibited locations. Barriers shall be located to prohibit permanent <br /> structures, equipment or similar objects from being used to climb them. <br /> AG105.5 Barriers. <br /> AG105.5.1 Enclosure; required characteristics. An enclosure shall have all of the <br /> following characteristics: <br /> 1. Any access gates through the enclosure open away from the swimming pool and <br /> are self - closing with a self - latching device placed no lower than 60 inches (1524 <br /> mm) above the ground. <br /> 2. A minimum height of 60 inches (1524 mm). <br /> 3. A maximum vertical clearance from the ground to the bottom of the enclosure of <br /> 2 inches (51 mm). <br /> 4. Gaps or voids, if any, do not allow passage of a sphere equal to or greater than 4 <br /> inches (102 mm) in diameter. <br /> 5. An outside surface free of protrusions, cavities or other physical characteristics <br /> that would serve as handholds or footholds that could enable a child below the <br /> age of five years to climb over. <br /> AG105.5.2 Barrier exceptions. Spas or hot tubs with locking safety covers that comply <br /> with the American Society for Testing Materials Emergency Performance Specification <br /> (ASTM ES 13 -89) or ASTM F 1346, as listed in Section AG107, shall be exempt from <br /> the provisions of this appendix. <br /> AG105.6 Barrier prerequisite to filling of pool. An inspection to verify pool barriers <br /> are installed, functional and in compliance with the approved plans shall occur and be <br /> approved by the Building and Safety Official before water may be introduced into any <br /> pool or spa. <br /> AG105.7 Existing pool and spa barriers. Any new or replacement pool barrier shall <br /> be constructed and maintained per the current barrier requirements in the section <br /> AG105.5.1. Any existing swimming pool, spa, swimming pool /spa enclosure repair may <br /> maintain the original barrier and latch height requirements lawfully in place at the time of <br /> the original permitted construction. <br /> Every person in possession of land within the City of Pleasanton, either as owner, <br /> purchaser under contract, lessee, tenant or licensee, upon which is situated a private <br /> swimming pool or spa, shall at all times maintain on the lot or premises upon which <br /> 49 <br />