Building and Safety Official, the interim, temporary or acting Building and Safety <br /> Official. <br /> 20.10.020 CRC Chapter 1 Division II is deleted. <br /> Chapter 1 Division II is deleted. <br /> 20.10.030 CRC Section R202 amended — Definitions <br /> Section R202 is amended by adding the following definition to read as follows: <br /> BALCONY, EXTERIOR, is an exterior floor projecting from and supported by a <br /> structure, without additional independent supports. <br /> 20.10.040 CRC Table R301.2(1) amended — Climate and Geographic Design <br /> Criteria <br /> Table R301.2(1) is amended to read as follows: <br /> TABLE R301.2(1) <br /> CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br /> SUBJECT TO DAMAGE ICE <br /> WIND DESIGN FROM BARRIER <br /> GROUND SEISMIC Frost WINTER UNDER- AIR MEAN <br /> SNOW Speed' Topographic DESIGN line DESIGN LAYMENT FLOOD FREEZING ANNUAL <br /> LOAD (mph) effects` CATEGORY' Weathering' depth Termite` TEMP REQUIRED" HAZARDS INDEX' TEMP <br /> 85 Do, Di, Very <br /> N/A mph NO D2, E negligible N/A Heavy 32° _ NO Footnote g 2% 58.7° <br /> For SI: 1 pound per square foot = 0.0479 kPa 1 mile per hour = 0.447 m/s. <br /> a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. <br /> The weathering column shall be filled in with the weathering index (i c., "negligible,' "moderate" or "severe ") for concrete as determined <br /> from the Weathering Probability Map [Figure R301.2(3)]. The grade of masonry units shall be determined from ASTM C 34, C 55, C 62, C <br /> 73,C 90,C 129,C 145,C 216 or 652. <br /> b. The frost line depth may require deeper footings than indicated in Figure R403.1(1). The City of Pleasanton does not require additional <br /> depth of footing below finish grade. <br /> c. The jurisdiction shall fill in this part of le table to indicate the need for protection depending on whether there has been a history of local <br /> subterranean termite damage. <br /> d. The jurisdiction shall fill in this part of tie table with the wind speed from the basic wind speed map [FigureR301.2(4)]. W ind exposure <br /> category shall be determined on a site - specific basis in accordance with Section R301.2.1.4. <br /> e. The outdoor design dry-bulb temperature was selected from the columns of 971/2- percent values for winter from Appendix D of the <br /> International Plumbing Code. <br /> 0 The jurisdiction shall till in this part oft ie table with the seismic design category determined from Section 123012 2.1_ <br /> g. The date of the City of Pleasanton's entry into the National Flood Insurance Program. May 5, 1971. <br /> The date(s) of the Flood Insurance .Study; August 3, 2009; September 30, 1997; September 19, 1984; June 1980 revised August 31, 1982. <br /> The panel numbers and dates of all currently effective FIRMs adopted by the City of Pleasanton, as amended: Panel 06001 CO304G; Panel <br /> 06001CO308G; Panel 0600ICO309G; Panel 06001CO316G, Panel 06001CO317G; Panel 06001CO318G; Panel 06001CO3190: Panel <br /> 06001CO328G; Panel 06001CO336G; Panel 06001CO337C Panel 06001CO339G; Panel 06001CO343G; Panel 06001C0460G; Panel <br /> 06001C0476G; Panel 06001C0480G; and Panel 06001C04850, all effective August 3, 2009. <br /> h. In accordance with Sections R905 2.7.1. R905.4.3.1. R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of <br /> local damage from the effects of ice damming, the jurisdiction shall 011 in this part of the table with "YES. Otherwise, the jurisdiction shall <br /> 511 in this part of the table with "NO." <br /> i. The City of Pleasanton selected the 100 -year (99 %) value on the National Climatic Data Center data table "Air Freezing Index- USA <br /> Method (Base 32 °)' at www.nede.noaa.gov/fpsf html. <br /> j. The City of Pleasanton selected the meal annual temperature from the National Climatic Data Center data table "Air Freezing Index -USA <br /> Method (Base 32 °F)" at www.ncdc.noaagov /fpsf.html. <br /> 42 <br />