Laserfiche WebLink
footing on either side of the supported wall. In all cases, as a minimum, one '' /z" <br /> (51mm) continuous rebar shall be placed at the top and at the bottom of all grade <br /> beams and spread footings. <br /> 20.08.110 CBC Section 1908.1.8 amended - ACI 318 section 22.10.1. <br /> Section 1908.1.8 is amended to read as follows: <br /> 1908.1.8 ACI 318, section 22.10. Delete ACI 318, section 22.10, and replace with the <br /> following: <br /> 22.10 - Plain concrete in structures assigned to seismic design category C, D, E or F. <br /> 22.10.1- Structures assigned to Seismic Design Category C, D, E or F shall not have <br /> elements of structural plain concrete, except as follows: <br /> (a) Isolated footings of plain concrete supporting pedestals or columns are <br /> permitted, provided the projection of the footing beyond the face of the supported <br /> member does not exceed the footing thickness. <br /> (b) Plain concrete footing supporting walls are permitted, provided the footings have <br /> at least two continuous longitudinal reinforcing bars. Bars shall not be smaller <br /> than No. 4 and shall have a total area of not less than 0.002 times the gross <br /> cross - sectional area of the footing. A minimum of one bar shall be provided at <br /> the top and bottom of the footing. Continuity of reinforcement shall be provided <br /> at corners and intersections. <br /> Exception: In detached one and two- family dwellings three stories or less in <br /> height and constructed with stud bearing walls, plain concrete footings with at <br /> least two continuous longitudinal reinforcing bars not smaller than No. 4 are <br /> permitted to have a total area of less than 0.002 times the gross cross — <br /> sectional area of the footing. <br /> 20.08.120 CBC Section 1910.1 amended - Minimum Slab Provisions. <br /> Section 1910.1 is amended to read as follows: <br /> 1910.1 General. The thickness of concrete floor slabs supported directly on the ground <br /> shall not be less than 31/2 inches (89 mm). A minimum 10 -mil (0.010 inch, .20mm) <br /> polyethylene moisture retarder with joints lapped not less than 6 inches (152 mm) shall <br /> be placed above a minimurn of 4- inches (102 mm) of crushed or angular rock capillary <br /> moisture barrier or other approved equivalent methods and materials used to provide <br /> slab - stability and moisture protection of the interior environment of the building. The <br /> capillary moisture barrier material shall have a maximum particle size of 3 / 4 -inch with no <br /> more than 10 percent smaller than 1 /4—inch. In order to promote a more uniform curing <br /> of the slab and to provide protection for the polyethylene moisture retarder, a minimum <br /> of two- inches of fine clean sand shall be placed directly over the moisture retarder. As <br /> a minimum and in all cases where a slab is to be placed inside of a building, the slab <br /> shall be reinforced with not less than six inches by six inches ten gauge welded wire <br /> 35 <br />