STANDARD CONDITIONS OF APPROVAL <br /> Fire <br /> 117. The project applicant or developer shall keep the site free of fire hazards from the start <br /> of lumber construction until the final inspection. <br /> 118. Prior to any construction framing, the project applicant or developer shall provide <br /> adequate fire protection facilities, including, but not limited to a water supply and water <br /> flow in conformance to the City's Fire Department Standards able to suppress a major <br /> fire. <br /> 119. All fire sprinkler system water flow and control valves shall be complete and serviceable <br /> prior to final inspection. Prior to the occupancy of a building having a fire alarm system, <br /> the Fire Department shall test and witness the operation of the fire alarm system. The <br /> project applicant or developer shall construct transit shelters with trash receptacles at <br /> locations determined by the Director of Community Development and the City Engineer. <br /> The shelter and trash receptacle design shall be approved by the Director of Community <br /> Development prior to issuance of project building permits. An encroachment permit shall <br /> be obtained prior to installation. Lighting shall be provided if determined necessary by <br /> the City Engineer. <br /> 120. All commercial, industrial, and multi - family residential occupancies shall have valve <br /> tamper and water flow connected to an Underwriters Laboratory (UL) listed Central <br /> Station Service. Fire Department plan check includes specifications, monitoring <br /> certificate(s), installation certificate and alarm company U.L. certificate. Fire alarm <br /> control panel and remote annunciation shall be at location(s) approved by the Fire <br /> Prevention Bureau. All systems shall be point identified by individual device and <br /> annunciated by device type and point. <br /> 121. Should any operation or business activity involve the use, storage or handling of <br /> hazardous materials, the firm shall be responsible for contacting the LPFD prior to <br /> commencing operations. Please contact the Hazardous Materials Coordinator at <br /> 925/454 -2361. <br /> 122. The proposed building(s) may have additional Fire Department requirements that can <br /> only be addressed by knowing the details of occupancy. These occupancy details shall <br /> be submitted to the Fire Department prior to submittal of construction plans to the <br /> Building Department. Details shall include but not be limited to the following: <br /> a) Type of storage <br /> b) Height of storage <br /> c) Aisle spacing <br /> d) Rack of bulk storage <br /> e) Palletized storage <br /> f) Type of occupancies within areas of the building(s) <br /> Based on the information received, there may be additional requirements such as: <br /> smoke and heat venting, in -rack sprinklers, increases in sprinkler design criteria, draft <br /> curtains, etc. <br /> 123. Electrical conduit shall be provided to each fire protection system control valve including <br /> all valve(s) at the water connections. The Livermore - Pleasanton Fire Department <br /> 31 <br />
The URL can be used to link to this page
Your browser does not support the video tag.