Laserfiche WebLink
requires electronic supervision of all valves for automatic sprinkler systems and fire <br /> protection systems. <br /> 121. Fire hydrants shall be installed at spacing not to exceed 300 feet. <br /> 122. Where Fire Department vehicle access through or around a site involves changes in <br /> direction or curves, minimum - turning radius shall be as follows. Inside radius of 45 feet <br /> and outside radius of 55 feet shall be provided to facilitate fire truck turning radius for <br /> entry and exit from the site. <br /> 123. Address numbers shall be installed on the front or primary entrance for all buildings. <br /> Minimum building address character size shall be 12-inch high by 1 -inch stroke. If a <br /> building is located greater than 50 feet from street frontage, character size shall be 16- <br /> inch high by 1 'h -inch stroke minimum. Where multiple accesses are provided, address <br /> or tenant space number shall be provided on each access and /or warehouse door and <br /> character size shall be no less than 4 -inch high by % -inch stroke. In all cases address <br /> numerals shall be of contrasting background and clearly visible in accordance with the <br /> Livermore - Pleasanton Fire Department Premises Identification Standards. This may <br /> warrant field verification and adjustments based upon topography, landscaping or other <br /> obstructions. Conditions of approval checklist shall be completed and attached to all <br /> plan checks submitted for approval indicating that all conditions have been satisfied. <br /> 124. The following items will be provided prior to any construction above the foundation or <br /> slab. (Note: Periodic inspections will be made for compliance.) <br /> a) Emergency vehicle access shall be provided to the site. If the Public Works <br /> Improvements are part of the project to access the site, an emergency vehicle <br /> access plan shall be submitted for review and approval. <br /> b) Site access shall be provided prior to any construction above the foundation or <br /> slab. Based on the Site Plan Approval the access shall be installed. <br /> c) Emergency vehicle access shall be a minimum of 20 feet in width. A clear height <br /> free of obstructions (power, cable, telephone lines, tree limbs, etc.) shall be <br /> provided. This clearance shall be a minimum of 13 feet, 6 inches. Inside turning <br /> radius of 45 feet and outside turning radius of 55 feet shall be provided. <br /> d) Buildings or portions of buildings or facilities exceeding 30 feet in height above the <br /> lowest level of fire department vehicle access shall be provided with approved fire <br /> apparatus access roads capable of accommodating fire department aerial <br /> apparatus. Fire apparatus access roads shall have a minimum unobstructed width <br /> of 26 feet in the immediate vicinity of any building or portion of building more than <br /> 30 feet in height. At least one of the required access routes meeting this condition <br /> shall be located within a minimum of 15 feet and a maximum of 30 feet from the <br /> building, and shall be positioned parallel to one entire side of the building. <br /> e) Buildings or facilities exceeding 62,000 square feet of gross building area shall be <br /> provided with two separate and approved fire apparatus access roads. The roads <br /> shall be placed a distance apart equal to not less than one half of the length of the <br /> maximum overall diagonal dimension of the property or area to be served, <br /> measured in a straight line between accesses. <br /> 31 <br />