41. That storm drainage swales, gutters, inlets, outfalls, and <br /> channels not within the area of a dedicated public street <br /> or public service easement approved by the City Engineer be <br /> privately maintained by the property owners or through an <br /> association approved by the City. <br /> <br /> 42. That approval of the water supply and distribution system be ~ <br /> withheld pending final design and until the developer has <br /> demonstrated to the satisfaction of the City Engineer that <br /> the proposed system meets both the immediate and long-range <br /> requirements for supplying water in this area. <br /> <br />43. That the developer comply with any and all applicable requirements <br /> of the cross-connections control and backflow prevention device <br /> programs required by the California Administrative Code, <br /> Title 17. <br /> <br />44. That approval for the number, type and location of fire <br /> hydrants be withheld pending final design, review by the <br /> Fire Marshal, and final review by the City Engineer. <br /> <br />45. That approval of the sanitary sewer system be withheld pending <br /> final design and until the developor has demonstrated to the <br /> satisfaction of the City Engineer that the proposed system is <br /> adequate, connects to an approved point of discharge, and meets <br /> both the immediate and long-range requirements of the sanitary <br /> system in this and all tributary areas. <br /> <br />46. That if a sanitary sewer lift station is installed for <br /> use by the development and if it is accepted by the City <br /> for maintenance and operation, an agreement shall be com- <br /> pleted between the City and the developer prior to the <br /> approval of the development to the effect that the developer <br /> will provide a maintenance and operation fund for a minimum <br /> ten year period. <br /> <br />47. That approval 6f the storm drainage system be withheld <br /> pending final design and until the developer has demonstrated <br /> to the satisfaction of the City Engineer that the system is <br /> adequate, connects to an approved point of discharge, meets <br /> any and all applicable requirements of the Alameda County <br /> Flood Control District - Zone 7, meets any and all applicable <br /> requirements of the Federal Emergency Management Flood <br /> Hazard Program, and meets the immediate and long-range <br /> requirements of this development and all upstream areas <br /> intended to be drained through this development. <br /> <br />48. That electric power distribution, gas distribution, <br /> communication service, and any required alarm systems be <br /> installed underground in a joint utility trench unless <br /> otherwise specifically approved by the City Engineer. <br /> <br /> Rev. 10/84 <br /> Rev. 5/86 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.