My WebLink
|
Help
|
About
|
Sign Out
ORD 1869
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1801 - 1900
>
ORD 1869
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:07 PM
Creation date
10/25/2002 4:11:53 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/1/2002
DOCUMENT NO
ORD 1869
DOCUMENT NAME
BUILDING CODES
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(B) Ampacity and Over current Device Ratings. Photo- <br />voltaic system currents shall be considered continuous. <br /> <br />(1) Sizing of Conductors and over current Devices. The <br />circuit conductors and over current devices shall be sized to <br />carry not less than 125 percent of the maximum currents as <br />computed in 690.8(A). The rating or setting of over current <br />devices shall be permitted in accordance with 240.4(B) and <br /> <br />Exception: Circuits containing an assembly, <br />together with its over current device(s), that is listed for <br />continuous operation at 100 percent of its rating shall be <br />permitted to be utilized at 100 percent of its rating. <br /> <br />(2) Internal Current Limitation. Over current protection for <br />photovoltaic output circuits with devices that internally <br />limit the current from the photovoltaic output circuit shall <br />be permitted to be rated at less than the value computed in <br />690.8(B)(1). This reduced rating shall be at least 125 per- <br />cent of the limited current value. Photovoltaic output circuit <br />conductors shall be sized in accordance with 690.8(B)(1). <br />Exception: An over current device in an assembly listed for <br />continuous operation at 100 percent of its rating shall be <br />permitted to be utilized at 100 percent of its rating. <br /> <br />(C) Systems with Multiple Direct-Current Voltages. For a <br />photovoltaic power source that has multiple output circuit <br />voltages and employs a common-return conductor, the <br />ampacity of the common-return conductor shall not be less <br />than the sum of the ampere ratings of the over current de- <br />vices of the individual output circuits. <br /> <br />(D) Sizing of Module Interconnection Conductors. Where a <br />single over current device is used to protect a set of two or <br />more parallel-connected module circuits, the ampacity of <br />each of the module interconnection conductors shall not be <br />less than the sum of the rating of the single fuse plus 125 <br />percent of the short-circuit current from the other parallel- <br />connected modules. <br /> <br />690.9 Over current Protection. <br /> <br />70 <br /> <br /> <br />