My WebLink
|
Help
|
About
|
Sign Out
ORD 1869
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1801 - 1900
>
ORD 1869
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:07 PM
Creation date
10/25/2002 4:11:53 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/1/2002
DOCUMENT NO
ORD 1869
DOCUMENT NAME
BUILDING CODES
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. Masonry elements designed primarily as flexural <br />members shall comply with Section 2108.2.6.2.5. <br /> <br />5. Steel elements designed primarily as flexural members or <br />tresses shall have bracing for both top and bottom beam <br />flanges or chords at the location of the support of the <br />discontinuous system and shall comply with the <br />requirements of AISC-Seismic Part I, Section 9.4b. <br /> <br />BASIC <br />SYSTEM2 <br /> <br />Section 20.08.040 Section 108.9 Inspections - Adopted <br /> <br />Section 108.9 of the California Building Standards Code 2001 Edition (24 <br /> C.C.R.), and including by reference the Uniform Building Code, <br /> 1997 Edition, is amended to read as follows: <br /> <br />Inspections. In addition to scheduled inspections required <br />herein, the Building Official shall inspect any existing <br />building or structure within the City when requested to do <br />so by an owner or person acting under authority of the <br />owner. Such request shall be made in writing on forms <br />furnished for such purpose. An application shall be signed <br />by the applicant who may be required to submit evidence to <br />indicate such authority. A statement of all findings shall be <br />sent to the applicant and owner and a record shall be kept <br />on file in the office of the Building Official. Applications <br />shall be accompanied by an inspection fee based on the <br />Fees and Charges Appendix in the Municipal Code. <br /> <br />20.08.042 Table 16-N -amended - STRUCTURAL SYSTEMS <br /> <br />Table 16-N of the California Building Standards Code 2001 <br /> Edition (24 C.C.R.), and including by reference the Uniform <br /> Building Code is amended to read as follows: <br /> <br />TABLE 16-N-STRUCTURAL SYSTEMS~ <br /> <br />STRUCTURAL LATERAL-FORCE-RESISTING <br /> DESCRIPTION <br /> <br />SYSTEM <br /> <br />LIMIT FOR <br />SEISMIC <br />ZONES 3 AND <br /> <br />20 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.