My WebLink
|
Help
|
About
|
Sign Out
PC 2001-02
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2000-2009
>
2001
>
PC 2001-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2006 9:32:40 AM
Creation date
3/8/2002 9:29:18 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
1/24/2001
DOCUMENT NO
PC 2001-02
DOCUMENT NAME
SOUTH FRONT INVESTORS
NOTES
PUD-04
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Resolution No. PC-01-02 <br />Page 13 <br /> <br />Police <br /> <br />67. <br /> <br />68. <br /> <br />69. <br /> <br />70. <br /> <br />71. <br /> <br />72. <br /> <br />73. <br /> <br />74. <br /> <br />75. <br /> <br />76. <br /> <br />If required by the Police Department, the building(s) shall be equipped with an <br />alarm system, the type to be approved by the Police Department and that this <br />system shall be installed prior to occupancy of the building. <br /> <br />The applicants shall seek City Council approval to allow on-site regulation of the <br />Vehicle Code for the site. <br /> <br />Engineering <br /> <br />The applicants shall submit a final grading and drainage plan prepared by a <br />licensed civil engineer depicting all final grades and on-site drainage control <br />measures, including concrete-lined V-ditches, to protect all cut and fill slopes <br />from surface water overflow. This plan shall be subject to the review and <br />approval of the City Engineer, Planning Director, and the Director of Building <br />Inspection prior to the issuance of any building permits. <br /> <br />The applicants shall submit a refundable cash bond for hazard and erosion control <br />prior to issuance of an Engineering or Building Department permit. The amount <br />of this bond will be determined by the City Engineer. <br /> <br />All drive aisles shall be signed for no parking except in designated parking areas. <br /> <br />The design for the line, grade, and structural sections for the streets serving this <br />development shall be subject to final review and approval by the City Engineer. <br /> <br />The applicants shall construct vertical P.C.C. curbs and gutters within this <br />development unless otherwise approved by the City Engineer. When the sidewalk <br />is adjacent to the curb and gutter, they shall be poured monolithically. <br /> <br />All existing wells on the site shall be removed or sealed, filled and abandoned <br />pursuant to Alameda County Ord. 73-68, prior to the start of grading operations <br />unless Zone 7 retains specific wells for observation wells, or special approval is <br />obtained from the City Engineer for temporary use of an existing well for <br />construction water. Any wells designated for abandonment or any wells, <br />encountered during construction, are to be destroyed in accordance with a permit <br />obtained from Zone 7. <br /> <br />All existing septic tanks or holding tanks shall be removed or sealed, filled, and <br />abandoned, pursuant to the requirements of the Alameda County Department of <br />Health Services. <br /> <br />The haul route for all materials to and from this development shall be approved by <br />the City Engineer prior to the issuance of an encroachment permit. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.