My WebLink
|
Help
|
About
|
Sign Out
RES 01008
City of Pleasanton
>
CITY CLERK
>
RESOLUTIONS
>
2000-2009
>
2001
>
RES 01008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2001 11:41:59 PM
Creation date
2/20/2001 11:33:31 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
1/23/2001
DOCUMENT NO
RES 01008
DOCUMENT NAME
ALVISO ADOBE
NOTES
MASTER PLAN
NOTES 3
PARK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
29. <br /> <br />30. <br /> <br />31. <br /> <br />32. <br /> <br />concrete gutter to an acceptable point of discharge. The minimum slope for concrete <br />gutter shall be 0.5%. <br /> <br />A sanitary sewer-sampling manhole shall be provided on each of the sanitary sewer <br />lateral from each building, unless otherwise waived by the Director of Building <br />Inspection. <br /> <br />Prior to issuance of a building permit, the project developer shall pay the applicable Zone <br />7 and City connection fees and water meter cost for any water meters, including <br />irrigation meters. Additionally, the developer shall pay any applicable DSRSD sewer <br />permit fee. <br /> <br />The project developer shall submit two copies of the site soils report to the Director of <br />Building Inspection for third party peer review and shall pay for such review at the time <br />specified by the Director, but in all cases before the issuance of a grading permit. <br /> <br />Building and sites plans are to be submitted to the Building Department on computer disk <br />in a format approved by the Director. Digitized information shall be submitted before <br />requesting a final inspection and should reflect as-built situs and architectural information <br />as approved by the Director. <br /> <br />Fire <br /> <br />33. <br /> <br />34. <br /> <br />35. <br /> <br />36. <br /> <br />The development shall meet all requirements of the Pleasanton Fire Code (Chapter 20.24 <br />of the Pleasanton Municipal Code). <br /> <br />The site shall be kept free of fire hazards from the start of construction to final <br />inspection. <br /> <br />The project developer shall ensure that fire protection facilities, including all surface <br />roads, fire hydrants, and a water supply capable of furnishing the required fire flow shall <br />be installed and serviceable prior to and during the time of construction. When alternate <br />methods of protection are as approved by the Fire Chief, this requirement may be waived <br />or modified. Proposed alternative methods of fire protection shall be submitted, in <br />writing, to the Fire Chief. Work on the alternative fire protection methods shall not start <br />without the approval of the Fire Chief. <br /> <br />Fire extinguishers shall be provided in accordance with the recommendation of the Fire <br />Chief. <br /> <br />37. Each gated park entry point shall have a Knox Box, as approved by the Fire Chief. Each <br /> Knox Box shall have the entry type and number of keys required by the Fire Chief. Keys <br /> <br />Case 31o. PDR-62 Page <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.